Release Notes
Resolution: You can do it through the Device Manager performing the following steps:
1. Open the Device Manager.
2. Expand the System devices list.
3. Right-click the device with a name of the form IMB Driver and select Uninstall.
4. Click OK to uninstall.
If you choose to install Server Administrator during Intel IMB driver installation, Server Administrator services may fail to start or Server
Administrator may have problems accessing sensor data.
Issue description: Wrong install directory is displayed during OMinstallation. (71022)
Broadcom/Intel provides Broadcom/Intel SNMP agent installers, and they do not support installation of these components in the custom
directory.
Issue description: On Server Administrator 8.3.0 while running the Repair option from Add or Remove Programs or Uninstall or Change
a program window, if an error occurs, use the Repair option in the MSI.
Issue description: Do not specify user profile folders such as a desktop folder C:\Users\administrator\Desktop as custom
installation paths for installing Server Administrator. It is because services running on the system account cannot access such folders.
Known Issues on Linux operating systems
Issue description: Server Administrator components get removed during an OS upgrade. (380137). During an OS upgrade, some of the
srvadmin packages may get removed.
Resolution: After an operating system upgrade, reinstall the Server Administrator since the srvadmin packages may not be applicable for
the upgraded operating system. Example: After upgrading SLES 10 to SLES 11, Server Administrator must be reinstalled as the SLES 10
srvadmin packages may not work with SLES 11.
Versions Affected: 8.4.0 and earlier
Issue description: Existing connection service lost after SLES 11 upgrade. (388955). Server Administrator version 6.x for Linux does not
have a functional Connection Service web GUI after upgrading SUSE Linux Enterprise Server 11 using Service Pack 1. Also, the installed
WS-MAN service for OMSA does not function.
Resolution: To prevent it:
1. Before upgrading SLES 11 operating system, manually uninstall the open-source packages like OpenWSMAN, SFCB, SFCC and
LibCmpiCppImpl packages with — nodeps option.
2. Upgrade the SLES11 operating system using Service Pack 1.
If the system is upgraded and is facing issues, then, reinstall the following Server Administrator packages from the install media:
rpm -Uhv srvadmin-iws-*.sles11.rpm --nodeps rpm -Uhv srvadmin-itunnelprocider-*.sles11.rpm –
nodeps
Versions Affected: 8.4.0 to 6.0
Issue description: On a system running supported Linux operating system (French), the System Administrator Shortcut is not available.
(124261)
Resolution: To connect to the local Server Administrator Web Server, open a web browser and then connect to the URL https://
localhost:1311 to access Server Administrator.
Issue description: Linux install script cannot be run from Virtual Media.
Resolution: Run this script from the local file system after un-mounting the virtual media. It avoids input or output errors that you may
otherwise encounter while using Virtual Media.
Versions Affected: 8.4.0 and earlier
Issue Description: YUM uninstall leaves services running. (410584)
If you are using methods other than the srvadmin-uninstall.sh command to uninstall Server Administrator RPM, the Server
Administrator service processes may still continue to run.
Resolution: To prevent it, run the srvadmin-services stop command to stop the Server Administrator services and then remove
the Server Administrator RPMs.
Versions Affected: 8.4.0 and earlier
4