Users Guide

name=value pair 1
config=
name=value pair 2 Description
lom 2: Configures lom2 port as the primary network for
remote access.
lom 3: Configures lom3 port as the primary network for
remote access.
lom 4: Configures lom4 port as the primary network for
remote access.
NOTE: The primarynw option is supported from
PowerEdge12G systems onward. If the primarynw is
set to dedicated, then set failovernw to none.
NOTE: If the primarynw is set to dedicated, then
set failovernw to none.
failovernw=none | lom1 | lom2 | lom3 |
lom4 | all
none: Configures the failover network to none.
lom 1: Configures the failover network to lom 1.
lom 2: Configures the failover network to lom 2.
lom 3: Configures the failover network to lom 3.
lom 4: Configures the failover network to lom 4.
all: Configures the failover network to all loms.
NOTE: The failovernw option is supported on
PowerEdge12G systems onward. Configure both
primarynw and failovernw to set the nicselection.
The primarynw and failovernw options cannot have
the same value.
NOTE: Configure both primarynw and failovernw to
set the nicselection. The primarynw and failovernw
options cannot have the same value.
NOTE: Failovernw requires license to configure the
ports. If the appropriate license is not installed or
has expired, the system displays an error message.
For more information, see
Dell License Manager
at
dell.com/openmanagemanuals.
ipaddress=IP
Sets the IP address if you have selected static as the IP
address source for the BMC LAN interface.
subnet=Subnet Sets a subnet mask if you have selected static as the IP
address source for the BMC LAN interface.
gateway=Gateway
Sets a gateway address if you have selected static as the
IP address source for the BMC LAN interface.
ipsource=static | dhcp | systemsoftware
static: Static if the IP address of the BMC LAN interface is
a fixed, assigned IP address.
dhcp: DHCP if the source of the IP address of the BMC
LAN interface is the dynamic host configuration protocol.