Users Guide

Example to Do a global rescan of all controllers. The omconfig command syntax for rescanning all controllers on
the system does not require a controller or enclosure ID.
NOTE: Global rescan is not supported on non-RAID SCSI and SAS controllers. Reboot the
system to make visible the configuration changes on non-RAID SCSI controllers.
Example
omconfig storage globalinfo action=globalrescan
Omconfig Set Hot Spare Protection Policy
Table 210. Omconfig Set Hot Spare Protection Policy
Description Sets the hot spare protection policy for dedicated or global hot spares. For more information, see the
Dell OpenManage Server Administrator Storage Management User’s Guide at dell.com/support/
manuals.
Syntax
omconfig storage globalinfo action= setprotectionpolicies type=dhs
raid=<r1 | r5 | r6 | r10 | r50 | r60 | all> hscount=<1-16>
warnlevel=<0-3> includeghsinvdstate=<yes | no>, where hscount is the number
of hot spares assigned to the virtual disk and warnlevel is the severity level you want to assign to
the generated alert, if this policy is violated. Use
hscount=0 warnlevel=0 to reset the
dedicated hot spare protection policy for the RAID level.
Example for Global hot spare protection policy
Example
omconfig storage globalinfo action=setprotectionpolicies type=dhs
hscount=1 warnlevel=1 includeghsinvdstate=yes
Omconfig global threshold for remaining rated write endurance
Table 211. Omconfig Global threshold for remaining rated write endurance
Description Sets the threshold value for Remaining Rated Write Endurance (RRWE) SMART attribute for SSDs.
When the remaining rate write endurance threshold drops below the configured threshold, an alert is
logged. For more information about Global Threshold for Remaining Rated Write Endurance, see the
Dell OpenManage Online Help.
Syntax
omconfig storage globalinfo
action=setremainingratedwriteendurancethreshold type=<sassata|
pciessd> threshold=<1-100>
Example to Settings supported for different threshold values for SAS, SATA and PCIe SSDs. The omconfig
command syntax for Threshold RRWE value is set between 0 to 100.
NOTE: The RRWE SMART attribute is not supported for SSDs connected to software RAID
Controllers.
Example
omconfig storage globalinfo
action=setremainingratedwriteendurancethreshold type=sassata
threshold=0.
Omconfig Connector Commands
The following table displays the omconfig command syntax required to execute connector tasks.
178