Users Guide

Omconfig Global Enable Smart Thermal Shutdown
By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of 0
or 50 degree Celsius. However, if you have implemented connector redundancy on the PV220S and PV221S enclosures you can
specify that only the enclosure and not the operating system and server are shut down when the enclosure reaches a critical
temperature of 0 or 50 degree Celsius. Specifying that only the enclosure is shut down during excessive temperatures is known as
Smart Thermal Shutdown. For more information about Smart Thermal Shutdown, see the Dell OpenManage Online Help.
Table 207. Omconfig Global Enable Smart Thermal Shutdown
Description Enables smart thermal shutdown.
Syntax
omconfig storage globalinfo action=enablests
Example to Enable thermal shutdown. The omconfig command syntax for enabling thermal shutdown does not
require a controller or enclosure ID.
NOTE: You can use the omreport storage globalinfo command to determine whether smart
thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is
also displayed by the Server Administrator graphical user interface (GUI). To locate this
status, select the Storage object and the Information/Configuration tab.
Example
omconfig storage globalinfo action=enablests
Omconfig Global Disable Smart Thermal Shutdown
If you have previously enabled smart thermal shutdown using the omconfig command, you can disable smart thermal shutdown and
return the system to its default setting. When smart thermal shutdown is disabled, the operating system and the server shuts down
when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius.
Table 208. Omconfig Global Disable Smart Thermal Shutdown
Description Disables smart thermal shutdown for all controllers.
Syntax
omconfig storage globalinfo action=disablests
Example to Disable thermal shutdown. The omconfig command syntax for disabling thermal shutdown does not
require a controller or enclosure ID.
NOTE: You can use the omreport storage globalinfo command to determine whether smart
thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is
also displayed in the GUI of Server Administrator. To locate this status, select the Storage
object and the Information/Configuration tab.
Example
omconfig storage globalinfo action=disablests
Omconfig Global Rescan Controller
Table 209. Omconfig Global Rescan Controller
Description Rescans all the controllers on the system. For more information about Global Rescan Controller, see
the Dell OpenManage Online Help.
Syntax
omconfig storage globalinfo action=globalrescan
177