Users Guide

omconfig Start Battery Learn Cycle
Table 204. Omconfig Start Battery Learn Cycle
Description Starts the battery learn cycle.
Syntax omconfig storage battery action=startlearn controller=id battery=id,
where id is the controller ID and battery ID as reported by the omreport command. To obtain this
value, type
omreport storage controller to display the controller IDs and then type
omreport storage battery controller=ID to display the ID for the controller battery.
Example to Start the learn cycle on controller 1.
Example
omconfig storage battery action=startlearn controller=1 battery=0
Omconfig Delay Battery Learn Cycle
Table 205. Omconfig Delay Battery Learn Cycle
Description Delays the battery learn cycle for a specified period of time. You can delay the battery learn cycle for
a maximum of seven days or 168 hours.
Syntax
omconfig storage battery action=delaylearn controller=id battery=id
days=d hours=h, where id is the controller ID and battery ID as reported by the omreport
command. To obtain this value, type omreport storage controller to display the controller
IDs and then type
omreport storage battery controller=ID to display the ID for the
controller battery.
Example to Delay the learn cycle for three days and 12 hours on controller 1.
Example
omconfig storage battery action=delaylearn controller=1 battery=0
days=3 hours=12
Omconfig Global Commands
The following table displays the omconfig command syntax required to execute the global commands. When executed, these
commands apply to all controllers. These global commands also correspond to the global tasks provided by the Storage tree view
object’s Information/Configuration subtab.
Table 206. Omconfig Global Commands
Required Command Levels
(1, 2, 3)
Optional name=value pairs
omconfig storage globalinfo
action=enablests
action=disablests
action=globalrescan
action=setprotectionpolicies type=ghs or dhs
action=setremainingratedwriteendurancethreshold type=sassata | pcie threshold=<1-100>
176