Users Guide
spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval= <1 to 24>(hours), where id is the
controller ID as reported by the omreport storage controller command.
NOTE: On PERC 7 controllers, only spindownunconfigureddrives, spindownhotspares, and
spindowntimeinterval parameters are supported.
NOTE: You can specify spinupstarttime and spinuptimeinterval only when you set
spindownconfigureddrives=enabled.
Example to Spin down drives that are not configured or hot spares that are unattended for 30 minutes
Example
omconfig storage controller action= setpdiskpwrmanagement
spindownunconfigureddrives= enabled spindownhotspares=enabled
spindowntimeinterval=30 controller=1
Omconfig set controller mode
Table 183. Omconfig set controller mode
Description Sets the mode of the controller to RAID or HBA.
Syntax
omconfig storage controller action=setcontrollermode controller=id mode=raid|
hba, where id is the controller ID as reported by the omreport storage controller command.
NOTE: If a virtual disk, hotspare, or encryption key is enabled on the controller, the controller mode
cannot be changed to HBA. Reboot the system for the change to take effect.
Example to Set the controller mode to HBA.
Example
omconfig storage controller action=setcontrollermode controller=1 mode=hba
Omconfig autoconfigure RAID-0
Table 184. Omconfig autoconfigure RAID-0
Description Automatically configures RAID–0 with all disks that are in ready state.
Syntax omconfig storage controller action=autoconfigureRAID0 controller=id , where id is the
controller ID as reported by the omreport storage controller command.
Example to Automatically configure RAID–0 with other disks.
Example
omconfig storage controller action=autoconfigureRAID0 controller=1
Omconfig Set Patrol Read Mode
Table 185. Omconfig Set Patrol Read Mode
Description Sets the patrol read mode for the controller.
Syntax
omconfig storage controller action= setpatrolreadmode controller=id mode=
manual|auto|disable, where id is the controller ID as reported by the omreport storage controller
command.
Example to Sets the patrol read on controller 1 to manual mode
169