Users Guide

NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs
for the physical disks attached to the controller.
Example to Bring physical disk 3 on connector 0 of controller 1 back online.
On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=online
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=online
controller=1 pdisk=0:2:30
Omconfig Assign Global Hot Spare
Table 116. omconfig Assign Global Hot Spare
Description
Assigns a physical disk as a global hot spare.
Syntax
omconfig storage pdisk
action=assignglobalhotspare controller=id
pdisk=<PDISKID> assign=yes, where id is the controller
ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage
controller
to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs
for the physical disks attached to the controller.
Example to Assign physical disk 3 on connector 0 of controller 1 as a global
hot spare. On a SAS controller, the physical disk resides in
enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk
action=assignglobalhotspare controller=1
pdisk=0:3 assign=yes
Example for SAS controllers
omconfig storage pdisk
action=assignglobalhotspare controller=1
pdisk=0:2:3 assign=yes
Omconfig Rebuild Physical Disk
Table 117. omconfig Rebuild Physical Disk
Description Rebuilds a failed physical disk. Rebuilding a disk may take several
hours. If you need to cancel the rebuild, use the Cancel Rebuild
task. For more information about Rebuild Physical Disk, see the
Dell OpenManage Online Help.
Syntax
omconfig storage pdisk action=rebuild
controller=id pdisk=<PDISKID>, where id is the
controller ID. The <PDISKID> variable specifies the physical
disk.
141