Users Guide
Example for SAS controllers
omconfig storage pdisk action=blink
controller=1 pdisk=0:2:0
Omconfig Unblink Physical Disk
Table 109. omconfig Unblink Physical Disk
Description
Unblinks the light (light emitting diode or LED display) on one or
more physical disks attached to a controller.
Syntax
omconfig storage pdisk action=unblink
controller=id pdisk=<PDISKID>, where id is the
controller ID. The <PDISKID> variable specifies the physical
disk.
NOTE: To obtain these values, type omreport storage
controller
to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs
for the physical disks attached to the controller.
Example to Unblink physical disk 0 on connector 0 of controller 1. On a SAS
controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=unblink
controller=1 pdisk=0:0
Example for SAS controllers
omconfig storage pdisk action=unblink
controller=1 pdisk=0:2:0
Omconfig Prepare To Remove Physical Disk
Table 110. omconfig Prepare To Remove Physical Disk
Description
Prepares a physical disk for removal.
Syntax
omconfig storage pdisk action=remove
controller=id pdisk=<PDISKID>, where id is the
controller ID. The <PDISKID> variable specifies the physical
disk.
NOTE: To obtain these values, type omreport storage
controller
to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs
for the physical disks attached to the controller.
Example to Prepares physical disk 3 on connector 0 of controller 1 for
removal. On a SAS controller, the physical disk resides in
enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=remove
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=remove
controller=1 pdisk=0:2:3
138