Users Guide

Required Command Levels (1, 2, 3) and
name=value pair
Optional name=value pairs Use
info=pwrsupplies where id is the controller
number and ENCLOSUREID is the
enclosure number. For example:
controller=0 enclosure=2
controller=id
enclosure=<ENCLOSUREID>
info=pwrsupplies index=n where id is the
controller number and ENCLOSUREID is
the enclosure number and n is the number
of a power supply. For example:
controller=0 enclosure=2
info=pwrsupplies index=1
Displays the specified power supply.
Omreport EMM Status
The following table describes the syntax for the omreport EMM commands:
NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware.
Table 97. Omreport EMM Commands
Required Command Levels (1, 2, 3) and
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
controller=id
enclosure=<ENCLOSUREID> info=emms
where id is the controller number and
ENCLOSUREID is the enclosure number.
For example: controller=0 enclosure=2
Displays the enclosure management
modules (EMMs) for the specified
enclosure.
controller=id
enclosure=<ENCLOSUREID> info=emms
index=n where id is the controller number
and ENCLOSUREID is the enclosure
number and n is the number of an EMM.
For example: controller=0 enclosure=2
info=emms index=1
Displays the specified EMMs.
Omreport Enclosure Slot Occupancy Report
The following table describes the syntax for the omreport Enclosure Slot Occupancy Report commands:
Table 98. Omreport Enclosure Slot Occupancy Report Commands
Required Command Levels (1, 2, 3) and
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
controller=id
enclosure=<ENCLOSUREID>
info=pdslotreport, where id is the
Displays the empty and occupied slot
details for the specified enclosure.
132