Users Guide
Event Name Description
event=voltfail Sets action or enables or disables alert generation when a voltage probe detects that the
voltage is too low for proper operation.
event=intdualsdcardcritical Sets actions that Server Administrator performs when an internal dual SD card critical
event occurs.
event=intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual SD card warning
is displayed.
event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual SD card is not
available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual
SD card is lost.
event=watchdogasr Enables or disables alert generation configured by the ASR when the system has hung or
is not responding.
Omconfig system snmptraptest or omconfig servermodule snmptraptest
Use the omconfig system snmptraptest or omconfig servermodule snmptraptest command to send the snmp test trap to the
destination address if Server Administrator SNMP component is configured in the configuration file.
The following table displays the valid parameters for the command:
Table 68. Parameters For Alert Action Command
Action Description
dest=<ipv4 address |
ipv6 address | fqdn>
Send the test trap to the destination IP address.
NOTE: This feature is not supported on VMware ESXi.
Omconfig System Events Or Omconfig Servermodule Events
Use the omconfig system events or omconfig servermodule events command to enable and disable SNMP traps for the
components on your system.
NOTE: Not all event types are present on the system.
There are four parameters in the name=value pair component of the omconfig system events command:
• Source
• Type
• Severity
• Index
Source
At present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source of event
notification for the system’s components.
omconfig system events source=snmptraps
or
omconfig servermodule events source=snmptraps
110