Users Guide

Example chassis intrusion actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion clearall=true
or
omconfig servermodule alertaction event=intrusion clearall=true
Commands for clearing logs
You can use the omconfig system or omconfig servermodule command to clear the following logs: the alert log, command log, and
hardware or ESM log.
To clear the contents of the alert log, type:
omconfig system alertlog action=clear
or
omconfig servermodule alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from displaying. Clearing the command log
resolves this condition.
To clear the contents of the command log, type:
omconfig system cmdlog action=clear
or
omconfig servermodule cmdlog action=clear
To clear the contents of the ESM log, type:
omconfig system esmlog action=clear
or
omconfig servermodule esmlog action=clear
NOTE: For more information about alert messages, see the
Dell OpenManage Server Administrator Messages Reference
Guide
at dell.com/support/manuals.
Omconfig system pedestinations or omconfig servermodule pedestinations
Use the omconfig system pedestinations or omconfig servermodule pedestinations command to set IP addresses for alert
destinations.
The following table displays the valid parameters for the command.
NOTE: You can either specify the index and IP address as parameters together or you can set only the community string
as a parameter.
NOTE: Index 1 to 4 accepts an IPv4 address and index 5 to 8 accepts an IPv6 address. On 12th generation of PowerEdge
systems with iDRAC7 specific versions, the index can accept IPv4, IPv6, or FQDN.
Table 65. Valid Parameters Of Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations
name=Value Pair Description
destenable=true | false
true: Enables an individual platform event filter destination after a valid IP address has been set.
false: Disables an individual platform event filter.
index=number Sets the index for the destination.
107