The failure threshold indicates that the temperature of the enclosure has gone below the minimum
threshold or exceeded the maximum threshold which may cause data loss. You cannot change the
default values for the failure threshold.
Related links
Enclosure Temperature Probes
Temperature Probe Properties And Tasks
Using Enclosure Temperature Probes
Checking The Temperature Of The Enclosure
Does my controller support this feature? See Supported Features.
To check the temperature:
1. In the Server Administrator window, under the system tree, click Storage dashboard.
2. Expand the tree view until the Temperatures object is displayed.
3. Select the Temperatures object. The temperature reported by the temperature probe is displayed in
celsius in the Reading column in the right pane.
Related links
Enclosure Temperature Probes
Temperature Probe Properties And Tasks
Changing The Warning Threshold On The Temperature Probe
The temperature probes are listed in the Temperature Probes section. To change the temperature
probe’s warning threshold:
1. Select the probes that you want to change.
2. Select Set new values in Set New Temperature Probe Values page.
3. Type the lowest acceptable temperature in celsius for the enclosure in the Minimum Warning
Threshold text box. The text box label indicates the range that you can specify.
4. Type the highest acceptable temperature in celsius for the enclosure in the Maximum Warning
Threshold text box. The text box label indicates the range that you can specify.
5. Click Apply Changes.
To return to the default values, Reset to default values and click Apply Changes. The default values
are displayed in the Minimum Warning Threshold and Maximum Warning Threshold text boxes.
NOTE: On some enclosures, Storage Management may experience a short delay before
displaying the current enclosure temperature and temperature probe status.
Related links
Storage Management May Delay Before Updating Temperature Probe Status
To Locate Set Temperature Probe Values In Storage Management
To locate this task in storage management:
1. In the Server Administrator window, under the system tree, expand Storage to display the controller
objects.
2. Expand a controller object.
3. Expand a connector object.
4. Select the enclosure object.
5. Click Information/Configuration.
6. Select Set Temperature Probe Values from the Enclosure Tasks drop-down menu.
113