Users Guide
Property Definition
Split Bus Part Number Displays the part number of the enclosure split bus module.
A split bus is indicated by a single triangle symbol on the
back of the enclosure.
Enclosure Part Number Displays the part number of the enclosure.
Enclosure Alarm Displays whether the alarm on the enclosure is enabled or
disabled.
Enclosure And Backplane Tasks
To execute a drop-down menu enclosure task:
1. In the Server Administrator window, under the system tree, expand Storage dashboard to display the
controller objects.
2. Expand a controller object.
3. Expand a connector object.
4. Select the Enclosure object.
5. Click Information/Configuration on the storage Properties screen.
6. Select a task from the Enclosure Tasks drop-down menu.
7. Click Execute.
Enclosure — Available Tasks
The drop-down menu enclosure tasks are:
• Enabling The Enclosure Alarm
• Disabling The Enclosure Alarm
• Setting Asset Data
• Blinking The LED On The Enclosure
• Setting The Temperature Probe Values
Enabling The Enclosure Alarm
Does my enclosure support this feature? See Supported Features.
Select the Enable Alarm task to enable the enclosure alarm. When enabled, the alarm turns on when any
of the following events occur:
• Enclosure temperature has exceeded the warning threshold.
• Power supply, fan, or enclosure management module — EMM has failed.
• Split bus is not installed. A split bus is indicated by a single triangle symbol on the back of the
enclosure.
Related links
Using Alarms To Detect Failures
Disabling The Enclosure Alarm
Does my enclosure support this feature? See Supported Features.
111