Users Guide
Property Definition
• Failed — The temperature probe has
encountered a failure and is no longer
functioning. Storage Management is unable to
communicate with the enclosure using SES
commands. The Failed state is displayed when
the enclosure does not respond to a status
query from Storage Management for any
reason. For example, disconnecting the cable
causes a Failed state.
• Minimum Warning Threshold Exceeded — The
temperature of the enclosure has dropped
below the minimum warning threshold.
• Maximum Warning Threshold Exceeded —
The temperature of the enclosure has
exceeded above the maximum warning
threshold.
• Missing — The temperature probe is not
present in the enclosure.
• Inactive — The temperature probe is present in
the enclosure, but the EMM that it monitors is
not installed.
Reading
Displays the current temperature of the enclosure
as reported by the temperature probe.
Warning Threshold The Minimum and Maximum properties indicate
the temperatures currently set for the Warning
threshold.
Failure Threshold The Minimum and Maximum properties indicate
the temperatures currently set for the Failure
threshold.
Related links
Enclosure Temperature Probes
Checking The Temperature Of The Enclosure
Setting The Temperature Probe Values
Enclosure Management Modules (EMMs)
The Enclosure Management Modules (EMMs) that are installed in the enclosure are displayed under the
EMMs object in the tree view. You can select the EMMs object to view the individual EMM modules and
their status information.
The enclosure may contain one or more EMMs. The EMM modules monitor components of the
enclosure. These components include:
• Fans
• Power supplies
• Temperature probes
• The insertion or removal of a physical disk
• The LEDs on the enclosure
106