Connectivity Guide

TrapID Name Description Severity Category Cause Support
ed by
RAC
Platfor
m
1016 alertDrscSE
L
Critical The
RAC has
detected a
new event in
the System
Event Log
with Severity:
Critical
Critical Error RAC detected a new
system event log with
critical severity (detailed
log info is in drsAlert
Message varbind).
All
1017 alertDrscSE
L 80
percentFull
The RAC
system event
log is 80% full
Major Status RAC detected system
event log is 80% full.
All
1018 alertDrscSE
L 90
percentFull
The RAC
system event
log is 90% full
Major Status RAC detected system
event log is 90% full.
All
1018 alertDrscSE
L 90
percentFull
The RAC
system event
log is 90% full
Major Status RAC detected system
event log is 90% full.
All
1020 alertDrscSE
L Normal
The RAC has
detected a
new event in
the System
Event Log
with Severity:
Normal
Informatio
n
Error RAC detected a new
system event log with
normal severity (detailed
log info is in drsAlert
Message varbind).
All
BMC Traps
The BMC monitors the system for critical events by communicating with various sensors on the system
board and by sending alerts and log events when certain parameters exceed their preset thresholds. All of
the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1.
TrapID Description Severity
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure
Cleared
Information
131330 Under-Voltage Problem (Lower
Critical - going low)
Critical
131458 Under-Voltage Problem Cleared Information
131841 Generic Critical Voltage Problem Critical
36