Connectivity Guide

CMC Power Information
The following MIB tables provide information on the chassis power.
Table 69. DRsChassisIndex
Name
drsChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only
Table 70. DRsPotentialPower
Name
drsPotentialPower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2
Description Defines the power (in watts) required by the chassis infrastructure, along
with the maximum power requirements for all systems currently turned
on.
Syntax DellPowerReading
Access Read-only
Table 71. DRsIdlePower
Name
drsIdlePower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3
Description Defines the power (in watts) required by the chassis infrastructure, along
with the minimum power requirements for all systems currently turned
on.
Syntax DellPowerReading
Access Read-only
Table 72. DRsMaxPowerSpecification
Name
drsMaxPowerSpecification
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.4
Description Defines the power limit (in watts) at which server throttling takes place.
Syntax DellPowerReading
Access Read-only
Table 73. DRsPowerSurplus
Name
drsPowerSurplus
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5
Description Defines the power surplus (in watts) remaining above the
drsPotentialPower reading.
23