Concept Guide
name=value pair 1
config=
name=value pair 2 Description
packet that contains the number of characters
as soon as this number of characters (or
greater) has been accepted from the
baseboard serial controller into the BMC.
enableipmi= true | false
true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false
true: Enables DRAC NIC.
false: Disables DRAC NIC
nicselection=sharedwithfailover
onall | nic1 |teamednic1nic2 |
dracnic
sharedwithfailoveronall: Configures the new
NIC selection option.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming
functionality.
dracnic: Enables DRAC NIC if DRAC 5 is
installed.
NOTE: The nicselection option is
supported only on PowerEdge 10G and
11G systems. From PowerEdge 12G
systems onwards, primarynw and
failovernw replaces nicselection.
primarynw=dedicated | lom1 |
lom2 | lom3 | lom4
dedicated: Configures dedicated port as
primary network for remote access.
NOTE: This option requires license to
configure primarynw as dedicated. If the
appropriate license is not installed or has
expired, the system displays an error
message. For more information, see Dell
License Manager at dell.com/
openmanagemanuals.
lom 1: Configures lom1 port as the primary
network for remote access.
lom 2: Configures lom2 port as the primary
network for remote access.
lom 3: Configures lom3 port as the primary
network for remote access.
lom 4: Configures lom4 port as the primary
network for remote access.
92