Concept Guide

Example to Start the learn cycle on controller 1.
Example
omconfig storage battery action=startlearn controller=1
battery=0
Omconfig Delay Battery Learn Cycle
Table 116. Omconfig Delay Battery Learn Cycle
Description Delays the battery learn cycle for a specified period of time. You can delay the
battery learn cycle for a maximum of seven days or 168 hours.
Syntax
omconfig storage battery action=delaylearn controller=id
battery=id days=d hours=h, where id is the controller ID and battery ID as
reported by the omreport command. To obtain this value, type omreport
storage controller
to display the controller IDs and then type omreport
storage battery controller=ID to display the ID for the controller
battery.
Example to Delay the learn cycle for three days and 12 hours on controller 1.
Example
omconfig storage battery action=delaylearn controller=1
battery=0 days=3 hours=12
Omconfig Global Commands
The following table displays the omconfig command syntax required to execute the global commands.
When executed, these commands apply to all controllers. These global commands also correspond to
the global tasks provided by the Storage tree view object’s Information/Configuration subtab.
Table 117. Omconfig Global Commands
Required Command
Levels (1, 2, 3)
Optional name=value pairs
omconfig storage
globalinfo
action=enablests
action=disablests
action=globalrescan
action=setprotectionpolicies type=ghs or dhs
action=setremainingratedwriteendurancethreshold type=sassata | pcie
threshold=<1-100>
Omconfig Global Enable Smart Thermal Shutdown
By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a
critical temperature of 0 or 50 degree Celsius. However, if you have implemented connector redundancy
on the PV220S and PV221S enclosures you can specify that only the enclosure and not the operating
system and server are shut down when the enclosure reaches a critical temperature of 0 or 50 degree
203