Concept Guide
clearredundantpath=clear
abortcheckconsistencyonerror=<enabled |
disabled> loadbalance=<auto | disabled>
allowrevertiblehotspareandreplacemember
=<enabled | disabled>
autoreplacememberonpredictivefailure=
<enabled | disabled>
persistenthotspare=<enabled | disabled>
nrdiskcachepolicy=<enabled | disabled |
unchanged>
Example to
Example
Enable revertible hot spare and replace member
operation.
omconfig storage controller action=
setchangecontrollerproperties
allowrevertiblehotspare
andreplacemember=enabled controller=1
Example to
Example
Allows to enable, disable, or not to change the
Non-RAID Hard Disk Drives. This is applicable only
to Disk Cache Policy.
omconfig storage controller action=
setchangecontrollerproperties
controller=1 nrdiskcachepolicy=enabled
Omconfig Discard Preserved Cache
Descriptio
n
Discards the preserved cache on the controller.
NOTE: To check if the controller has a preserved cache, type omreport storage
controller controller=id. If the system displays Preserved Cache=yes, it
indicates the presence of the preserved cache.
Syntax
omconfig storage controller action= discardpreservedcache
controller=id force=enabled | disabled
If you set force=enabled, the cache is discarded irrespective of whether the controller
detects a foreign or an offline virtual disk.
Example
to
Discard the preserved cache.
Example
omconfig storage controller action= discardpreservedcache
controller=1 force=enabled
CAUTION: Discarding the preserved cache can result in data loss. It is recommended
that you run this command using the force=disabled option.