Concept Guide

Event Name Description
event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual
SD card is not available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy
of an internal dual SD card is lost.
event=watchdogasr Enables or disables alert generation configured by the ASR when the
system has hung or is not responding.
Omconfig system snmptraptest or omconfig servermodule snmptraptest
Use the omconfig system snmptraptest or omconfig servermodule snmptraptest command to send the
snmp test trap to the destination address if Server Administrator SNMP component is configured in the
configuration file.
The following table displays the valid parameters for the command:
Table 46. Parameters For Alert Action Command
Action Description
dest=<ipv4 address
| ipv6 address |
fqdn>
Send the test trap to the destination IP address.
NOTE: This feature is not supported on VMWare ESXi.
Omconfig System Events Or Omconfig Servermodule Events
Use the omconfig system events or omconfig servermodule events command to enable and disable
SNMP traps for the components on your system.
NOTE: Not all event types are present on the system.
There are four parameters in the name=value pair component of the omconfig system events command:
Source
Type
Severity
Index
Source
At present, source=snmptraps is a required name=value pair because SNMP is currently the only
supported source of event notification for the system’s components.
omconfig system events source=snmptraps
or
omconfig servermodule events source=snmptraps
Type
Type refers to the name of the component(s) involved in the event. The following table displays the valid
parameters for system event types.
126