Users Guide

Property Definition
Ready—The temperature probe is functioning normally.
Degraded—The temperature probe has encountered a failure
and is operating in a degraded state.
Failed—The temperature probe has encountered a failure and
is no longer functioning. Storage Management is unable to
communicate with the enclosure using SES commands. The
Failed state is displayed when the enclosure does not respond
to a status query from Storage Management for any reason.
For example, disconnecting the cable causes a Failed state.
Minimum Warning Threshold Exceeded—The temperature
of the enclosure has dropped below the minimum warning
threshold.
Maximum Warning Threshold Exceeded—The temperature
of the enclosure has exceeded above the maximum warning
threshold.
Missing — The temperature probe is not present in the
enclosure.
Inactive — The temperature probe is present in the enclosure,
but the EMM that it monitors is not installed.
Reading Displays the current temperature of the enclosure as reported by
the temperature probe.
Warning Threshold The Minimum and Maximum properties indicate the
temperatures currently set for the Warning threshold.
Failure Threshold The Minimum and Maximum properties indicate the
temperatures currently set for the Failure threshold.
Related concepts
Enclosure Temperature Probes
Related tasks
Checking The Temperature Of The Enclosure
Setting The Temperature Probe Values
Enclosure Management Modules (EMMs)
The Enclosure Management Modules (EMMs) that are installed in the enclosure are displayed under the EMMs object in the tree view.
You can select the EMMs object to view the individual EMM modules and their status information.
The enclosure may contain one or more EMMs. The EMM modules monitor components of the enclosure. These components include:
Fans
Power supplies
Temperature probes
The insertion or removal of a physical disk
The LEDs on the enclosure
When the alarm on the enclosure is enabled, the EMM activates the alarm when certain conditions occur. For more information on
enabling the alarm and the conditions that activate the alarm, see Enabling The Enclosure Alarm. For more information on EMMs, see the
enclosure hardware documentation.
All EMM modules in the enclosure should have the same version of firmware. You can view the properties of each individual EMM module
to verify the firmware version.
Verifying The EMM Firmware Version Of The Enclosure
Does my controller support this feature? See Supported Features.
86