Users Guide

Related concepts
Choosing RAID Levels And Concatenation
Maintaining The Integrity Of Redundant Virtual
Disks
Does my controller support this feature? See Supported Features.
The virtual disk Check Consistency task verifies the accuracy of the redundant (parity) information. This task only applies to redundant
virtual disks. When necessary, the Check Consistency task rebuilds the redundant data.
To verify redundant information of a virtual disk:
1. Locate the controller on which the virtual disk resides in the tree view. Expand the controller object until the Virtual Disks object is
displayed.
2. Select the Check Consistency task from the virtual disk’s Tasks drop-down list box and click Execute.
Rebuilding Redundant Information
Does my controller support this feature? See Supported Features.
If you have a redundant virtual disk, you can reconstruct the contents of a failed physical disk onto a new disk or a hot spare. A rebuild can
take place during normal operation, but it degrades performance.
Related concepts
Replacing A Failed Disk
Setting The Rebuild Rate
A Rebuild Does Not Work
Managing Virtual Disk Bad Block Management
Virtual disk bad blocks are bad blocks on one or more member physical disks. The read operation on the virtual disks having bad blocks
may fail.
Storage Management generates a critical alert (2387) to notify you of the bad blocks on the virtual disk.
Virtual disk bad blocks are discovered when the controller performs any operation that requires scanning the disk. Examples of operations
that may result in this alert are:
Consistency check
Rebuild
Virtual disk format
I/O
Patrol Read
Recovering a physical disk bad block depends on the RAID level and state of the virtual disk. If a virtual disk is redundant, the controller can
recover a bad block on a physical disk. If a virtual disk is not redundant, then the physical disk bad block results in a virtual disk bad block.
Table 29. Sample Scenarios For Virtual Disk Bad Blocks
RAID Level Virtual Disk State Scenario Result
RAID 0 Degraded One bad block on a physical
disk.
The controller cannot
regenerate data from the peer
disks as there is no redundancy.
This results in a virtual disk bad
block.
RAID 5 Ready One bad block on a physical
disk.
The controller regenerates data
from the peer disks and sends a
Write to the bad block. The disk
then remaps the Logical Block
120 Virtual Disks