Connectivity Guide

Managed Object Used in This Document
The MIB is divided into several major groups. The following table provides information about the MIB names, name of the agent that uses
each MIB and the purpose:
MIB Name Agent / Hardware Supported Purpose of the MIB
10892.mib Server Administrator Provides the information about the systems monitored by
Server Administrator instrumentation software. This is the
primary MIB for PowerEdge systems.
dcs3fru.mib Server Administrator Provides the information about the system Field
Replaceable Unit (FRU) to SNMP management
applications.
dcstorag.mib Server Administrator Storage
Management
Provides the information about the storage hardware
components and RAID configurations monitored by Server
Administrator.
iDRAC-SMIv1.mib iDRAC7 and iDRAC 8 Provides information about the SNMP data and traps
supported by iDRAC7 and iDRAC8. This is the SMIv1
version of the iDRAC MIB.
iDRAC-SMIv2.mib iDRAC7 and iDRAC 8 Provides information about the SNMP data and traps
supported by iDRAC7 and iDRAC8. This is the SMIv2
version of the iDRAC MIB.
dcs3rmt.mib Dell Remote Access controller 5 (DRAC 5) Provides information about remote access components
monitored by the Server Administrator Remote Access
Service.
rac_host.mib Remote access out-of-band agent Provides information about the components monitored by
the remote access out-of-band software agent.
DELL-RAC-MIB.txt Chassis Management Controller (CMC) Provides information about components monitored by the
Chassis Management Controller for modular chassis. This
MIB is the legacy iDRAC MIB. Changes made in this MIB
are not for iDRAC. iDRAC does not support all the objects
and traps defined in this MIB. The new and more extensive
iDRAC MIB is available for iDRAC7 and later versions.
DcAsfSrv.mib Baseboard Management Controller (BMC) Provides information about Dell server Platform Event
Traps generated by the Baseboard Management
Controller.
For further details see Release Notes for Management Information Base readme_mibs.txt.
Server Administrator Instrumentation MIB
The Server Administrator Instrumentation MIB ( filename 10892.mib ) provides instrumentation data that allows you to monitor the
health of a system with SNMP management applications. It provides:
Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at key points in the system
Rapid access to detailed fault and performance information gathered by industry standard systems management agents
Version information for Basic Input/Output System (BIOS), firmware, and operating system
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related
information. The below table describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to
the MIB group. The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group
number>, where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information
about the MIB objects defined in a MIB group.
Introduction