Connectivity Guide
Description Line Item Explanation
SD card device type: <Type
of SD card device>
Specifies the type of SD card device, for example:
SD card device type: Hypervisor
SD card state: <State of SD
card>
Specifies the state of the SD card, for example:
SD card state: Present, Failed
Sensor location: <Location
in chassis>
Specifies the location of the sensor in the specified chassis, for example:
Sensor location: CPU1
Temperature sensor value
(in degrees Celsius):
<Reading>
Specifies the temperature in degrees Celsius, for example:
Temperature sensor value (in degrees Celsius): 30
Voltage sensor value (in
Volts): <Reading>
Specifies the voltage sensor value in volts, for example:
Voltage sensor value: 1.693
Understanding Trap Severity
Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components for values
such as amperage, voltage, and temperature. When an event occurs on your system, the Server Administrator sends information about
one of the following event types to the system management console:
• Information/Informational—An event that describes the successful operation of a unit, such as a power supply turning on or a
sensor reading returning to normal.
• Warning — An event that is not necessarily significant, but may indicate a possible future problem, such as crossing a warning
threshold.
• Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function, such as crossing a failure
threshold or a hardware failure.
BMC Traps
The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and
log events when certain parameters exceed their preset thresholds. All of the traps documented in this section belong to the MIB
enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1.
TrapID
Description Severity
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Information
131330 Under-Voltage Problem (Lower Critical -
going low)
Critical
131458 Under-Voltage Problem Cleared Information
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem Cleared Information
65792 Under-Temperature Warning (Lower non-
critical, going low)
Warning
65920 Under-Temperature Warning Cleared Information
65794 Under-Temperature Problem (Lower Critical
- going low)
Critical
65922 Under-Temperature Problem Cleared Information
65799 Over-Temperature warning (Upper non-
critical, going high)
Minor
65927 Over-Temperature warning Cleared Information