Connectivity Guide
Description Line Item Explanation
Device location: <Location
in chassis>
Specifies the location of the device in the specified chassis, for example:
Device location: Mem Card A
Discrete current state:
<State>
Specifies the state of the current sensor, for example:
Discrete current state: Good
Discrete temperature state:
<State>
Specifies the state of the temperature sensor, for example:
Discrete temperature state: Good
Discrete voltage state:
<State>
Specifies the state of the voltage sensor, for example:
Discrete voltage state: Good
Fan sensor value: <Reading>
Specifies the fan speed in revolutions per minute (RPMs) or On/Off, for example:
Fan sensor value (in RPM): 2600
Fan sensor value: Off
Log type: <Log type>
Specifies the type of hardware log, for example:
Log type: Embedded Server Management (ESM)
Memory device bank
location: <Bank name in
chassis>
Specifies the name of the memory bank in the system that generated the message, for
example:
Memory device bank location: Bank_1
Memory device location:
<Device name in chassis>
Specifies the location of the memory module in the chassis, for example:
Memory device location: DIMM_A
Number of devices required
for full redundancy:
<Number>
Specifies the number of power supply or cooling devices required to achieve full redundancy,
for example:
Number of devices required for full redundancy: 4
Peak value (in Watts):
<Reading>
Specifies the peak value in Watts, for example:
Peak value (in Watts): 125
Possible memory module
event cause: <list of
causes>
Specifies a list of possible causes for the memory module event, for example:
Possible memory module event cause: Single bit warning error rate
exceeded
Single bit error logging disabled
Power Supply type: <type of
power supply>
Specifies the type of power supply, for example:
Power Supply type: VRM
Pre-failure state was:
<State>
Specifies the status of the previous memory message, for example:
Pre-failure state was: Failed
Previous redundancy state
was: <State>
Specifies the status of the previous redundancy message, for example:
Previous redundancy state was: Lost
Previous state was: <State>
Specifies the previous state of the sensor, for example:
Previous state was: OK (Normal)
Processor sensor status:
<status>
Specifies the status of the processor sensor, for example:
Processor sensor status: Configuration error
Redundancy unit:
<Redundancy location in
chassis>
Specifies the location of the redundant power supply or cooling unit in the chassis, for example:
Redundancy unit: Fan Enclosure
380 SNMP Traps