Connectivity Guide
Object ID 1.3.6.1.4.1.674.10892.4.5000.10.9
Description Specifies the system service tag of the system generating the alert.
Syntax DisplayString
Table 1820. Chassis Service Tag
Variable Name
alertChassisServiceTag
Object ID 1.3.6.1.4.1.674.10892.4.5000.10.10
Description Specifies the chassis service tag of the system generating the alert.
Syntax DisplayString
Understanding The Trap Description
The below table lists in alphabetical order each line item that may appear in the trap description.
Table 1821. Trap Description
Description Line Item Explanation
Action performed was:
<Action>
Specifies the automatic server recovery action that was performed, for example:
Action performed was: Power cycle
Action requested was:
<Action>
Specifies the user initiated host control action that was requested, for example:
Action requested was: Reboot, shutdown OS first
Additional details:
<Additional details for the
events>
Specifies possible additional details about the specified device, for example:
Additional details:
Memory device: DIMM_1A Serial number: 11111111
Memory device: DIMM_1B Serial number: 22222222
<Additional power supply
status information>
Specifies any additional power supply information pertaining to the event, for example:
Power supply input AC is off, Power supply POK (power OK) signal
is not normal, Power supply is turned off
Battery sensor status:
<status>
Specifies the status reported by the battery sensor, for example:
Battery sensor status: Predictive failure
Chassis intrusion state:
<Intrusion state>
Specifies the chassis intrusion state (open or closed), for example:
Chassis intrusion state: Open
Chassis location: <Name of
chassis>
Specifies the name of the chassis that generated the message, for example:
Chassis location: Main System Chassis
Configuration error type:
<type of configuration
error>
Specifies the type of configuration error that occurred, for example:
Configuration error type: Revision mismatch
Current sensor value (in
Amps): <Reading>
Specifies the current sensor value in amps, for example:
Current sensor value: 7.853
Date and time of action:
<Date and time>
Specifies the date and time that an automatic server recovery action was performed, for
example:
Date and time of action: Fri May 30 23:55:44 2003.
Description: <Description
of event>
Specifies the description of the event that occurred, for example:
Description: Chipset Err: Critical Event sensor, front panel NMI /
diagnostic interrupt was asserted.