Connectivity Guide
Access Read-only
Table 1388. Agent Smart Thermal Shutdown
Name
agentSmartThermalShutdown
Object ID 1.3.6.1.4.1.674.10893.1.20.110.15
Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S
enclosures.
Possible values:
1: Enabled
2: Disabled
3: Not applicable
Syntax Integer
Access Read-only
Physical Devices Group
The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their
relationships to each other. The following MIB tables define objects and relationships (connections) among the objects.
• Controller Table — describes available properties for each controller on the managed system.
• Channel Table — describes available properties for each channel on the managed system.
• Enclosure Table — describes available properties for each enclosure on the managed system.
• Array Disk Table — describes available properties for each physical array disk on the managed system.
• Array Disk Enclosure Connection Table — describes the connections between Fibre Channel array disks, their enclosure, and their
associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table
for that object where all of the object properties can be found.
• Array Disk Channel Connection Table — describes the connections between SCSI array disks, their channel, and their associated
controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that
object where all of the object properties can be found.
• Fan Table — describes available properties for each fan on the managed system.
• Fan Connection Table — describes the connection between each fan on the managed system and its enclosure. Each enclosure
number in the table corresponds to that enclosure instance in the Enclosure Table.
• Power Supply Table — describes available properties for each power supply on the managed system.
• Power Supply Connection Table — describes the connection between each power supply on the managed system and its
enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table.
• Temperature Probe Table — describes available properties for each temperature probe on the managed system.
• Temperature Probe Connection Table — describes the connection between each temperature probe on the managed system and
its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table.
• EMM Table — describes available properties for each Enclosure Management Module (EMM) on the managed system.
• EMM Connection Table — describes the connection between each EMM on the managed system and its enclosure. Each enclosure
number in the table corresponds to that enclosure instance in the Enclosure Table.
• Battery Table — describes available properties for each controller battery on the managed system.
• Battery Connection Table — describes the connection between each battery on the managed system and its controller. Each
controller number in the table corresponds to that controller instance in the Controller Table.
Controller Table
This table describes available properties for each controller on the managed system.
The following object sets up the Controller Table.
Table 1389. Controller Table
Name
controllerTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1
294 Storage Management Group