Release Notes
Use one of these methods to correct this issue:
o Change your passwords before updating the firmware.
o Use the following CLI command to change the password: "omconfig rac users
username=xx userpassword=yy" where "xx" is the original user ID and "yy" is the new
password.
o Change the password through Server Administrator using the "User" tab. Make sure that the
check box to change the password is checked. Enter a new password, and then enter it
again to validate the change.
Use the racadm utility to change the password: "racadm config -g
cfgUserAdmin -o cfgUserAdminPassword -i <usr_index> <new_pwd>" where
<usr_index> is the index of the user database entry to be modified and <new_pwd>
is the new password.
• Depending on your network and proxy configurations and whether you are using Mozilla browser,
you may need to enter the exact IP address of the RAC controller, you are trying to access in the
"No Proxy for" field of your browser.
Perform the following steps:
1. Open your Mozilla browser.
2. Click "Edit".
3. Click "Preferences".
4. Click "Advanced" in the left sidebar.
5. Click "Proxies" in the left sidebar.
6. Enter the RAC IP address in the "No Proxy for:" field.
7. Click "OK" and then close the browser.
• To view the RAC Web-based interface when using Mozilla 1.6, you must configure your cookie
settings to "Enable all cookies".
• To enable all cookies, go to the menu options and click "Edit -> Preferences -> Privacy & Security -
> Cookies", and then select "Enable all cookies". If you do not perform these steps, you cannot log
on to the Web interface and a message appears indicating that your username and password are
incorrect.
• DF384362: "Redundancy Status" displays as "Not Applicable" in ESXi even when NICs are teamed.
On VMware ESXi systems, NIC teaming status may not display up in the Server Administrator
network section. This is an expected behavior due to the operating system limitation and has no
functional impact to the system.
• DF384061: Self-signed certificate does not enable the compatibility listener in Windows 2008 R2
managed node. On a Windows 2008 R2 managed node, a valid CA signed certificate is required to
create compatibility mode WinRM Listener. You cannot create a compatibility mode listener with a
self-signed certificate.
• DF380725: On Internet Explorer or Firefox Web browsers, you cannot attach files to an e- mail if the
filename contains non-ASCII letters. To attach files to an e-mail, rename files to contain ASCII
characters.
• On 12th generation of PowerEdge servers, Server Administrator displays the Embedded Systems
Management (ESM) or hardware logs. However, when the maximum limit for number of logs that
can be recorded is reached, the existing oldest logs are overwritten. But for 11th generation of
PowerEdge servers or prior, when the maximum limit is reached, the information logging is
stopped.
• DF523827: On Citrix XenServer 6.0 or later, if the Alert on Console alert action is configured from
the Server Administrator CLI or GUI, the alert message may not be displayed in a readable format.
• BITS113585: Server Administrator does not log CPU or CMOS Battery Probe Alerts and does not
send SNMP traps.