Release Notes

BITS050574: On 11th generation and 12th generation of PowerEdge servers running the Linux OS,
the omreport system summary command displays “RAC Command Interface” as 7.1.0. “RAC
Command Interface” is a DRAC4 RPM and its version is 7.1. It is installed as a dependent package for
iDRAC6 and iDRAC7 Command Interface packages.
If a new certificate imported to Server Administrator is not active after restarting the Web server,
restore the previous certificate.
To restore the previous certificate, do the following:
1. Stop the Web server.
2. Perform one of the following as applicable: On systems running
Windows:
Delete the file keystore.db at <installed directory>\Dell\SysMgt\apache-
tomcat\conf\
Rename the file keystore.db.bak at <installed directory>\Dell\SysMgt\apache-
tomcat\conf\to keystore.db
On systems running Linux:
o For 32-bit OS
Delete the keystore.db file at /opt/dell/srvadmin/lib/openmanage/apache-
tomcat/conf
Rename the keystore.db.bak at /opt/dell/srvadmin/lib/openmanage/apache-
tomcat/conf to keystore.db
o For 64-bit OS
Delete the keystore.db file at /opt/dell/srvadmin/lib64/openmanage/apache-
tomcat/conf
Rename the keystore.db.bak at
/opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to keystore.db
3. Start the Web server.
BITS078118: On 12th generation of PowerEdge servers with specific versions of iDRAC, you cannot
set the platform event alert actions (reboot, shut down, and so on) through Server Administrator.
Set the alert actions for the events through iDRAC GUI.
BITS130401: On 12th generation of PowerEdge servers, you cannot set the BIOS setup password
from the GUI. Use the CLI to set the password
BITS144583: On Mozilla Firefox 21 or later, the "Quit browser" option does not work after logging
out from Server Administrator. To close the browser or tab, you must manually close the Firefox
browser tab.
BITS177670: On Chrome 38 or later, the "Quit browser" option does not work after logging out from
Server Administrator. To close the browser or tab, you must manually close the Firefox browser tab.
On PowerEdge T430, C4130, and R220 II, with PERC S130 configuration and no backplane, Storage
Management displays a mock backplane which does not support the blink/unblink operation for
disks available on this configuration.
BITS192754: Execute Disable(XD) capability value is displayed as NO in OMSA GUI though it is
supported.