Reference Guide

MIB Name Agent / Hardware Supported Purpose of the MIB
iDRAC-SMIv1.mib iDRAC7 and iDRAC 8 Provides information about the SNMP data
and traps supported by iDRAC7 and iDRAC8.
This is the SMIv1 version of the iDRAC MIB.
iDRAC-SMIv2.mib iDRAC7 and iDRAC 8 Provides information about the SNMP data
and traps supported by iDRAC7 and iDRAC8.
This is the SMIv2 version of the iDRAC MIB.
dcs3rmt.mib Dell Remote Access controller 5
(DRAC 5)
Provides information about remote access
components monitored by the Server
Administrator Remote Access Service.
rac_host.mib Remote access out-of-band
agent
Provides information about the components
monitored by the remote access out-of-
band software agent.
DELL-RAC-MIB.txt Chassis Management Controller
(CMC)
Provides information about components
monitored by the Chassis Management
Controller for modular chassis. This MIB is
the legacy iDRAC MIB. Changes made in this
MIB are not for iDRAC. iDRAC does not
support all the objects and traps defined in
this MIB. The new and more extensive iDRAC
MIB is available for iDRAC7 and later
versions.
DcAsfSrv.mib Baseboard Management
Controller (BMC)
Provides information about Dell server
Platform Event Traps generated by the
Baseboard Management Controller.
For further details see Release Notes for Management Information Base readme_mibs.txt.
Server Administrator Instrumentation MIB
The Server Administrator Instrumentation MIB ( filename 10892.mib ) provides instrumentation data that
allows you to monitor the health of a system with SNMP management applications. It provides:
Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at
key points in the system
Rapid access to detailed fault and performance information gathered by industry standard systems
management agents
Version information for Basic Input/Output System (BIOS), firmware, and operating system
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or
MIB tables that provide related information. The below table describes each Server Administrator
Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server
Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB
group number>, where <MIB group number> is the MIB group number assigned to the MIB group. See
the relevant section for more information about the MIB objects defined in a MIB group.
8