Connectivity Guide

1
Introduction
This reference guide provides information about Simple Network Management Protocol (SNMP)
Management Information Base (MIB) which are released with the current version of Dell iDRAC and
Chassis Management Controller.
Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to
define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this
guide. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using
SNMP for the first time.
Supported SNMP Versions
iDRAC version SNMP Alerts / Traps SNMP Gets
iDRAC7 SNMP v1 ,v2, v3 v1,v2,v3
iDRAC8 SNMP v1,v2,v3 v1,v2,v3
NOTE: SNMP alerts and traps v3 is supported on iDRAC7 for firmware version 2.10.10.10 and later
systems.
Managed Object Used in This Document
The MIB is divided into several major groups. The following table provides information about the MIB
names, name of the agent that uses each MIB and the purpose:
MIB Name Agent / Hardware Supported Purpose of the MIB
10892.mib Server Administrator Provides the information about the systems
monitored by Server Administrator
instrumentation software. This is the primary
MIB for PowerEdge systems.
dcs3fru.mib Server Administrator Provides the information about the system
Field Replaceable Unit (FRU) to SNMP
management applications.
dcstorag.mib Server Administrator Storage
Management
Provides the information about the storage
hardware components and RAID
configurations monitored by Server
Administrator.
iDRAC-SMIv1.mib iDRAC7 and iDRAC 8 Provides information about the SNMP data
and traps supported by iDRAC7 and iDRAC8.
This is the SMIv1 version of the iDRAC MIB.
5