Connectivity Guide
Table 103. DRsServerAssignedServerSlots
Name
drsServerAssignedServerSlots
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.12
Description This attribute defines the server slots to which a storage sled is assigned.
If this is a storage sled that is assigned to one more or more server slots,
the value will be a comma-separated list of one or more server slot
names. If the storage sled is not assigned to a server slot, the value will
be an empty string. If this is not a storage sled, the value will be N/A.
Syntax DellString
Access Read-only
Chassis Alert
The following MIB tables provide information on the chassis management controller alerts.
Table 104. DRsCASubSystem
Name
drsCASubSystem
Object ID 1.3.6.1.4.1.674.10892.2.20.10.1
Description Defines the subsystem name of the CMC Alert.
Syntax DellString
Access Read-only
Table 105. DrsCASSCurrStatus
Name
drsCASSCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.20.10.2
Description Defines the current status of the alerting subsystem.
Syntax DellStatus
Access Read-only
Table 106. DrsCASSPrevStatus
Name
drsCASSPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.20.10.3
Description Defines the previous status of the alerting subsystem.
Syntax DellStatus
Access Read-only
Table 107. DrsCASSChangeTime
Name
drsCASSChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.20.10.4
30