Connectivity Guide

Table 79. DRsWattsMinTime
Name
drsWattsMinTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11
Description Defines the time stamp of the most recent chassis minimum power
usage.
Syntax DellPowerReading
Access Read-only
Table 80. DRsWattsResetTime
Name
drsWattsResetTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12
Description Defines the time stamp of the most recent reset of the chassis
minimum/maximum watts readings.
Syntax DellTimestamp
Access Read-only
Table 81. DRsWattsReading
Name
drsWattsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13
Description Defines the instantaneous chassis power usage (in watts).
Syntax DellPowerReading
Access Read-only
Table 82. DRsAmpsReading
Name
drsAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14
Description Defines the instantaneous chassis current usage (in watts).
Syntax DellPowerReading
Access Read-only
CMC PSU Information
The following MIB tables provide information on the chassis power supply units.
Table 83. DRsPSUChassisIndex
Name
drsPSUChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
25