Users Guide
Omconfig set controller mode
Descriptio
n
Sets the mode of the controller to RAID or HBA.
Syntax
omconfig storage controller action=setcontrollermode controller=id
mode=raid|hba, where id is the controller ID as reported by the omreport storage
controller command.
NOTE: If a virtual disk, hotspare, or encryption key is enabled on the controller, the
controller mode cannot be changed to HBA. Reboot the system for the change to take
effect.
Example
to
Set the controller mode to HBA.
Example
omconfig storage controller action=setcontrollermode controller=1
mode=hba
Omconfig autoconfigure RAID-0
Descriptio
n
Automatically configures RAID–0 with all disks that are in ready state.
Syntax omconfig storage controller action=autoconfigureRAID0 controller=id ,
where id is the controller ID as reported by the omreport storage controller command.
Example
to
Automatically configure RAID–0 with other disks.
Example
omconfig storage controller action=autoconfigureRAID0 controller=1
Omconfig Set Patrol Read Mode
Descriptio
n
Sets the patrol read mode for the controller.
Syntax
omconfig storage controller action= setpatrolreadmode controller=id
mode= manual|auto|disable, where id is the controller ID as reported by the
omreport storage controller command.
Example
to
Sets the patrol read on controller 1 to manual mode
Example
omconfig storage controller action= setpatrolreadmode controller=1
mode=manual
195