Users Guide
Omconfig Export Reliability Log
Description
Exports log on a physical disk or the NVMe adapter.
The reliability log for the device PCIe SSD device or
NVMe device is exported to the Windows folder on
systems running Windows, and to /var/log
directory on systems running Linux.
Syntax
omconfig storage pdisk action=exportlog
controller=id pdisk=<PDISKID>, where id is
the controller ID. The <PDISKID> variable specifies
the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller IDs
and then type omreport storage pdisk
controller=ID to display the IDs for the
physical disks attached to the controller.
NOTE: Depending on the PCIe SSD or MVMe
device the log file name will be
PCIeSSD_<device name>_<timestamp>.log or
NVMe_<device name>_<timestamp>.log
where the <device name> is the name of the
device and timestamp is month, day, hour,
minute and second during which the
command is executed.
Example to Export log on physical disk 3 on connector 0 of
controller 1. On a SAS controller, the physical disk
resides in enclosure 2.
Example for SAS controllers
omconfig storage pdisk action=exportlog
controller=1 pdisk=0:2:3
Omconfig Convert RAID To Non-RAID
Description
Converts RAID to non-RAID on a physical disk.
Syntax
omconfig storage pdisk
action=convertraidtononraid
controller=id pdisk=<PDISKID>, where id is
the controller ID. The <PDISKID> variable specifies
the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller IDs
and then type omreport storage pdisk
controller=ID to display the IDs for the
physical disks attached to the controller.
167