Users Guide

If the communication channel between the connector and the first enclosure is lost, the redundant path
configuration is lost. In this case, the health of the logical connector is displayed as critical. Navigate to
the
Information/Configuration page of the logical connector to view details of the Path Health. For a
brief outline of this scenario, see the following table:
Table 14. Path between Controller and Enclosure 1
Health of Logical Connector Path between Controller and Enclosure 1
Connector 0 (C0) Connector 1 (C1)
Available Available
Available Disconnected
Disconnected Available
However, if the communication channel between any two enclosures is lost, the redundant path
configuration is degraded and the health of the logical connector is displayed as degraded. For a brief
outline of this scenario, see the following table.
Table 15. Path between Enclosure
n and Enclosure n +1
Health of Logical Connector Path between Enclosure n and Enclosure n +1
Connector 0 (C0) Connector 1 (C1)
Available Available
Available Disconnected
81