Users Guide

Property Definition
State Displays the status of the enclosure or backplane. Possible
values are:
Ready — The enclosure or backplane is functioning
normally.
Degraded — The enclosure has encountered a failure
and is operating in a degraded state. This state does not
apply to backplanes.
Failed — The enclosure or backplane has encountered a
failure and is no longer functioning.
Connector Displays the number of connectors attached to the
enclosures or backplanes. This number matches the number
connector on the controller hardware. Depending on the
controller type, the connector can be either a SCSI channel
or a SAS port.
Enclosure ID Displays the enclosure ID assigned to the enclosure by
Storage Management. Storage Management numbers the
enclosures attached to the controller starting with zero. This
number is the same as the enclosure ID number reported by
the omreport command. For information on Command Line
Interface, see the Server Administrator Command Line
Interface User’s Guide.
Target ID Displays the SCSI ID of the backplane (internal to the server)
or the enclosure to which the controller connector is
attached. The default value is six.
Configuration Displays the mode in which the enclosure is operating.
Possible values are:
Joined — Indicates that the enclosure is operating in the
joined-bus mode.
Split — Indicates that the enclosure is operating in the
split-bus mode.
Unified — Indicates that enclosure is operating in the
unified mode.
Clustered — Indicates that the enclosure is operating in
cluster mode. Clustered mode is only available on
cluster-enabled RAID controllers. For more information,
see Background Initialization On PERC Controllers.
For more information on joined, split, and cluster modes,
see the enclosure hardware documentation. For information
on how to cable the enclosure to accommodate these
different modes, see the enclosure hardware
documentation.
The bus configuration switch when toggled on a 220S or
221S enclosure, the enclosure should be turned off. For
more information, see Changing The Mode On 220S And
221S Enclosures.
Older 200S enclosures with a version 1.8 kernel that only
have one EMM may display Split Bus mode and not Joined
109