Release Notes

values to the values that were saved in the configuration file as the default. If the system
running the VMware ESXi operating system is reset without a graceful shutdown before the
changes to the configuration file are updated to the disk, the user- defined thresholds
become the default thresholds.
DF315853: Some Server Administrator CLI commands, function properly only when run from the
elevated console window. It is recommended that you use the elevated console for running the
CLI.
Due to some limitations, you cannot log on simultaneously to multiple browser instances/tabs
using SSO login, as only one session remains active while the other sessions expire.
DF489034: Intel TXT configuration fails due to Virtualization technology dependency
If the current Virtualization Technology attribute setting is "Disabled" (Virtualization Technology is
part of the Processor Settings group on the BIOS setup page); the Intel TXT attribute configuration
fails on the Server Administrator user interface (System -> Main System Chassis -> BIOS -> Setup -
>System Security.) To resolve this issue, configure Virtualization technology setting to "Enabled"
and reconfigure the Intel TXT attribute, if it is configurable.
DF549057: When an operating system is installed through USC, the BIOS attributes in Server
Administrator are displayed as read-only. You can edit the BIOS attributes 18 hours after the
operating system installation.
Workaround: To enable editing of the Server Administrator BIOS attributes, launch Lifecycle
Controller while booting.
DF552204: On Mozilla Firefox browsers (versions 10, 11 and 12), Server Administrator fails to launch
if IPv6 address is used.
This is a known issue. For more information, see
https://bugzilla.mozilla.org/show_bug.cgi?id=633001.
BITS040169: In case of Boot/HDD/UEFI sequence, if they are read-only, then toggle buttons (+ and
-) and submit button are not visible. On the BIOS setup page, dependencies may exist between the
various attributes for Bios settings. Setting an attribute value may change the state of the
dependent attributes to non-editable or editable. For example, changing the Boot Mode to UEFI
from the Boot Settings page does not allow you to configure the Boot or Hard-Disk Drive Sequence
in the BIOS Boot Settings page. When the page is non-editable, the toggle buttons on the page
allows toggling the order of the boot sequence. However, settings cannot be configured since
“Apply” button will not available to submit the settings.
BITS050574: On 11
th
generation and 12
th
generation of PowerEdge servers running the Linux OS,
the omreport system summary command displays “RAC Command Interface” as 7.1.0. “RAC
Command Interface” is a DRAC4 RPM and its version is 7.1. It is installed as a dependent package for
iDRAC6 and iDRAC7 Command Interface packages.
If a new certificate imported to Server Administrator is not active after restarting the Web server,
restore the previous certificate.
To restore the previous certificate, do the following:
1. Stop the Web server.
2. Perform one of the following as applicable: On systems running
Windows:
Delete the file keystore.db at <installed directory>\Dell\SysMgt\apache-
tomcat\conf\
Rename the file keystore.db.bak at <installed directory>\Dell\SysMgt\apache-
tomcat\conf\to keystore.db
On systems running Linux:
o For 32-bit OS
Delete the keystore.db file at /opt/dell/srvadmin/lib/openmanage/apache-