Release Notes
Workaround: Perform the following and manage the remote system from the web server.
1.
Configure TCP Chimney offload to disable state by running the following command:
netsh int tcp set global chimney=disabled
2.
Configure RSS (Receive Side Scaling) to disable state by running the following command:
netsh int tcp set global rss=disabled
3.
Configure NetDMA to disable state by running the following command:
netsh int tcp set global NetDMA=disabled
• BITS086423: After an upgrade to the current version, Server Administrator does not retain the
support link information on the Preferences page.
• BITS091830: Distributed Web Server (DWS) connection does not work if you have installed the
sblim-sfcb rpm from SLES11 SP3 operating system DVD. To make the connection work, install
sblim-sfcb rpm either from SLES11 SP2 or from OM DVD.
• BITS040184: User in IDRAC user authentication page showing operator privilege(IDRAC user
privileges) is displayed as Custom in Server Administrator.
• With the following wsman rpm versions getting carried in SLES12 OS,OMSA DWS does not work.
Update these rpms having same or later versions from SUSE
openwsman-server-2.4.11-2.18.x86_64.rpm ,libwsman1-2.4.11-2.18.x86_64.rpm,
libwsman_clientpp1-2.4.11-2.18.x86_64.rpm