Release Notes
• To view the RAC Web-based interface when using Mozilla 1.6, you must configure your cookie
settings to "Enable all cookies".
• To enable all cookies, go to the menu options and click "Edit -> Preferences -> Privacy & Security -
> Cookies", and then select "Enable all cookies". If you do not perform these steps, you cannot log
on to the Web interface and a message appears indicating that your username and password are
incorrect.
• DF384362: "Redundancy Status" displays as "Not Applicable" in ESXi even when NICs are teamed.
On VMware ESXi systems, NIC teaming status may not display up in the Server Administrator
network section. This is an expected behavior due to the operating system limitation and has no
functional impact to the system.
• DF384061: Self-signed certificate does not enable the compatibility listener in Windows 2008 R2
managed node. On a Windows 2008 R2 managed node, a valid CA signed certificate is required to
create compatibility mode WinRM Listener. You cannot create a compatibility mode listener with a
self-signed certificate.
• DF380725: On Internet Explorer or Firefox Web browsers, you cannot attach files to an e- mail if the
filename contains non-ASCII letters. To attach files to an e-mail, rename files to contain ASCII
characters.
• On 12
th
generation of PowerEdge servers, Server Administrator displays the Embedded Systems
Management (ESM) or hardware logs. However, when the maximum limit for number of logs that
can be recorded is reached, the existing oldest logs are overwritten. But for 11
th
generation of
PowerEdge servers or prior, when the maximum limit is reached, the information logging is
stopped.
• DF523827: On Citrix XenServer 6.0 or later, if the Alert on Console alert action is configured from
the Server Administrator CLI or GUI, the alert message may not be displayed in a readable format.
• BITS113585: Server Administrator does not log CPU or CMOS Battery Probe Alerts and does not
send SNMP traps.
To resolve this issue, stop the USB arbitration service and run the Inventory Collector.
To stop the USB arbitration service:
1. Run the “ps aux|grep usb” command to check if the USB arbitration service is running.
2. Run the “chkconfig usbarbitrator off” command to prevent the USB arbitration service
from starting during boot.
3. After the USB arbitrator service is stopped, reboot the server to allow the Inventory
collector to run.
• DF520449: On all versions of the ESX, the following USB connection error messages are generated.
These messages can be ignored.
The following is a typical message:
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
Vendor: iDRAC Model: SECUPD Rev: 0329
Type: Direct-Access ANSI SCSI revision: 02
(520449)
• DF531509: The setup and/or system password configuration from the Server Administrator GUI or
CLI is successful, but the password is displayed as blank instead of asterisk (*) on the F2 BIOS page.
• DF532055: From Windows Server 2008 R2 SP1, when an administrator manages Red Hat Enterprise
Linux 6.1 (64-bit) or 5.7 (32 and 64-bit) operating systems, Server Administrator reports connection
error intermittently.