Users Guide
For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is optional. Also, you can
now specify the spanlength as an even number with a maximum of 8 spans with 32 physical disks each.
For example:
omconfig storage controller action=createvdisk controller=1 raid=r10 size=min
pdisk= 1:1:0,1:1:1,1:1:3,1:1:4,1:1:6,1:1:7,1:1:8,1:1:9
spanlength=4
Omconfig Set Controller Rebuild Rate
Descriptio
n
Sets the controller rebuild rate.
Syntax
omconfig storage controller action=setrebuildrate controller=id
rate=<0 to 100>, where id is the controller ID as reported by the omreport storage
controller command.
Example
to
Set the rebuild rate to 50 on controller 1.
Example
omconfig storage controller action=setrebuildrate controller=1
rate=50
omconfig Change Controller Properties
Table 101. omconfig Change Controller Properties
Description
Changes any or all of the controller properties.
Syntax
omconfig storage controller action=
setchangecontrollerproperties
controller=<id> bgirate=<rate>
reconstructrate=<rate>
checkconsistencyrate=<rate>
rebuildrate=<rate>
clearredundantpath=clear
abortcheckconsistencyonerror=<enabled |
disabled> loadbalance=<auto | disabled>
allowrevertiblehotspareandreplacemember
=<enabled | disabled>
autoreplacememberonpredictivefailure=
<enabled | disabled>
persistenthotspare=<enabled | disabled>
Example to Enable allow revertible hot spare and replace
member operation.
Example
omconfig storage controller action=
setchangecontrollerproperties
allowrevertiblehotspare
andreplacemember=enabled controller=1