Users Guide
NOTE: For RAID 10 creation, PERC 9 firmware suggests the layout (number of array disks) with
uneven span (spans with unequal number of array disks), though in a span the number of disks
remains even. For example, for 32 disks, RAID 10 gets created with all the disks in one span and for
34 disks, RAID 10 gets created with 16 disks in one span and 18 disks in the other span.
Example Syntax:
You can create a RAID-5 virtual disk of 500 MB with a stripe size of 16 KB on a PERC 3/QC controller. The
name of the virtual disk is vd1 and it resides on connector 0 of controller 1. Because the virtual disk is a
RAID-5, it requires at least three physical disks. In this example, you specify four physical disks. These are
physical disks 0 through 3. The virtual disk has read-ahead, write–through caching, and cache I/O
policies.
To create a virtual disk:
omconfig storage controller action=createvdisk controller=1 raid=r5 size=500m
pdisk= 0:0,0:1,0:2,0:3 stripesize=16kb cachepolicy=c readpolicy=ra
writepolicy=wt
The only parameters that require specification are for the controller, RAID level, virtual disk size, and
physical disk selection. Storage Management supplies default values for all other unspecified parameters.
For more information on read, write, and cache policies that are supported by the controller, see the Dell
OpenManage Online Help.
Parameter specification for creating and reconfiguring virtual disk
The following table displays how to specify the omconfig storage controller action=createvdisk
parameters:
Table 88. Parameters And Types
Parameters Type
controller=id Required
raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> Required
size=<number | max | min> Required
pdisk=<connector:targetID,connector:targetID,.....
>
Required
[stripesize=<2k b| 4kb | 8kb | 16kb | 32kb | 64kb |
128kb>]
Optional
[cachepolicy=<d | c>] Optional
[readpolicy=<ra | nra | ara | rc | nrc>] Optional
[writepolicy=<wb | wt | wc | nwc | fwb>] Optional
[name=<string>] Optional
[spanlength=<n>] parameter Optional
controller=id parameter
181