Dell OpenManage SNMP Reference Guide for iDRAC8 and Chassis Management Controller
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction........................................................................................................... 5 What’s new in this release..................................................................................................................... 5 Supported SNMP Versions.................................................................................................................... 6 Managed Object Used in This Document.......................................................
Rack and Tower Servers................................................................................................................ 51 iDRAC8 Supported SNMP Versions.....................................................................................................51 iDRAC8 SNMP Data Security Features............................................................................................... 52 iDRAC8 Out-of-Band Group...................................................................................
Introduction 1 This reference guide provides information about Simple Network Management Protocol (SNMP) Management Information Base (MIB) which are released with the current version of Dell iDRAC8 and Chassis Management Controller. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this guide.
• * alertNetworkConfigurationInformation * alertNetworkConfigurationWarning Added new varbinds and Traps for Dell Chassis Management Controller Group – Added new varbinds in the following sub groups: Product Information * drsProductChassisSize CMC Server Information * drsServerNodeID.
Managed Object Used in This Document The MIB is divided into several major groups. The following table provides information about the MIB names, name of the agent that uses each MIB and the purpose: MIB Name Agent / Hardware Supported Purpose of the MIB 10892.mib Server Administrator Provides the information about the systems monitored by Server Administrator instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.
The Server Administrator Remote Access MIB ( filename dcs3rmt.mib ) provides in-band information about remote access hardware that may be present in your system. The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table below describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group.
Topics • • MIB Group Number Chassis Alerts Legacy Alerting Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at dell.com/ support/manuals.
has a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID. The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value. These objects comprise the Server Administrator definitions for the UUID. Table 3. UUID Table Name uUIDTable Object ID 1.3.6.
Table 7. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 8. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis.
Chassis Management Controller Group 2 Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB attributes provide product information for the chassis management controller: Table 9. DRsProductName Name drsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Description Defines the product manufacturer of a chassis management controller. Syntax DellString Access Read-only Table 13. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 14. DRsChassisServiceTag Name drsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis.
Table 18. DRsProductChassisName Name drsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Table 19. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 20. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Description Defines the data center locator of the chassis. Syntax DellString Access Read-only Table 24. DRsProductChassisAisle Name drsProductChassisAisle Object ID 1.3.6.1.4.1.674.10892.2.1.1.16 Description Defines the aisle locator of the chassis. Syntax DellString Access Read-only Table 25. DRsProductChassisRack Name drsProductChassisRack Object ID 1.3.6.1.4.1.674.10892.2.1.1.17 Description Defines the rack locator of the chassis. Syntax DellString Access Read-only Table 26.
Table 29. DRsProductChassisSystemID Name drsProductChassisSystemID Object ID 1.3.6.1.4.1.674.10892.2.1.1.21 Description Defines the system ID of the chassis. Syntax INTEGER Access Read-only Table 30. DRsProductChassisSize Name drsProductChassisSize Object ID 1.3.6.1.4.1.674.10892.2.1.1.22 Description Defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component. Syntax INTEGER Access Read-only Table 31.
Chassis Status The following MIB attributes provide status information on the chassis being monitored by the chassis management controller. Table 34. DRsGlobalSystemStatus Name drsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 35. DRsGlobalCurrStatus Name drsGlobalCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.
Description Defines the redundancy status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 39. DRsPowerCurrStatus Name drsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 40. DRsFanCurrStatus Name drsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.
Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 44. DRsChassisFrontPanelAmbientTemperature Name drsChassisFrontPanelAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.10 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. Syntax DellTemperatureReading Access Read-only Table 45.
Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 49. DRsKVMPrevStatus Name drsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 50. DRsRedPrevStatus Name drsRedPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.
Description Defines the previous blade subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 54. DRsTempPrevStatus Name drsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 55. DRsCMCPrevStatus Name drsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.
Syntax TimeTicks Access Read-only Table 59. DRsRedChangeTime Name drsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only Table 60. DRsPowerChangeTime Name drsPowerChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.5 Description Defines the timestamp of the most recent power health status change. Syntax TimeTicks Access Read-only Table 61.
Table 64. DRsCMCChangeTime Name drsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change. Syntax TimeTicks Access Read-only Chassis Power The following MIB tables provide power information for the chassis being monitored by the chassis management controller. Table 65. DRsCMC Power Table Name drsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table.
CMC Power Information The following MIB tables provide information on the chassis power. Table 69. DRsChassisIndex Name drsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only Table 70. DRsPotentialPower Name drsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
Syntax DellPowerReading Access Read-only Table 74. DRsKWhCumulative Name drsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only Table 75. DRsKWhCumulativeTime Name drsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset.
Table 79. DRsWattsMinTime Name drsWattsMinTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11 Description Defines the time stamp of the most recent chassis minimum power usage. Syntax DellPowerReading Access Read-only Table 80. DRsWattsResetTime Name drsWattsResetTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12 Description Defines the time stamp of the most recent reset of the chassis minimum/maximum watts readings. Syntax DellTimestamp Access Read-only Table 81.
Access Read-only Table 84. DRsPSUIndex Name drsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only Table 85. DRsPSULocation Name drsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only Table 86. DRsPSUMonitoringCapable Name drsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.
Table 89. DRsPSUWattsReading Name drsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU wattage reading. Syntax DellPowerReading Access Read-only Chassis Servers The following MIB tables provide server information for the chassis being monitored by the chassis management controller. Table 90. DRsCMCServerTable Name drsCMCServerTable Object ID 1.3.6.1.4.1.674.10892.2.5.1 Description Defines the CMC server table.
Table 93. DRsServerMonitoringCapable Name drsServerMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.2 Description Defines the monitoring capabilities, or the absence of a server in this location. Syntax DellCMCServerCapable Access Read-only Table 94. DRsServerServiceTag Name drsServerServiceTag Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.3 Description Defines the Service Tag of the CMC server. Syntax DellString Access Read-only Table 95.
Chassis Alert The following MIB tables provide information on the chassis management controller alerts. Table 98. DRsCASubSystem Name drsCASubSystem Object ID 1.3.6.1.4.1.674.10892.2.20.10.1 Description Defines the subsystem name of the CMC Alert. Syntax DellString Access Read-only Table 99. DrsCASSCurrStatus Name drsCASSCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.2 Description Defines the current status of the alerting subsystem. Syntax DellStatus Access Read-only Table 100.
Chassis Alert 2 Table 103. DRsCA2MessageID Name drsCA2MessageID Object ID 1.3.6.1.4.1.674.10892.2.21.10.1 Description Defines the message ID of the alert. Syntax DisplayString Access Read-only Table 104. DrsCA2Message Name drsCA2Message Object ID 1.3.6.1.4.1.674.10892.2.21.10.2 Description Defines the message describing the alert. Syntax DellString Access Read-only Table 105. DrsCA2MessageArgs Name drsCA2MessageArgs Object ID 1.3.6.1.4.1.674.10892.2.21.10.
Description Defines the fully qualified device descriptor of device causing the alert. Syntax DisplayString Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 108. DRsAlertSystem Name drsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax Octet String Access Read-only Table 109. DRsAlertTableIndexOID Name drsAlertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.2.
Syntax DellStatus Access Read-only Table 113. DRsAlertData Name drsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
SNMP Traps 3 SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section. The trap variables are sent in the order in which they are listed. NOTE: The PowerEdge M1000e CMC, PowerEdge VRTX CMC and PowerEdge FX2 CMC do not generate the traps in this section.
TrapID Name Description Severity Category detected a new event in the System Event Log with Severity: Critical Cause Support ed by RAC Platfor m critical severity (detailed log info is in drsAlert Message varbind). 1017 alertDrscSE L 80 percentFull The RAC system event log is 80% full Major Status RAC detected system event log is 80% full. All 1018 alertDrscSE L 90 percentFull The RAC system event log is 90% full Major Status RAC detected system event log is 90% full.
TrapID Description Severity 65792 Under-Temperature Warning (Lower non-critical, going low) Warning 65920 Under-Temperature Warning Cleared Information 65794 Under-Temperature Problem (Lower Critical - going low) Critical 65922 Under-Temperature Problem Cleared Information 65799 Over-Temperature warning (Upper non-critical, going high) Minor 65927 Over-Temperature warning Cleared Information 65801 Over-Temperature Problem (Upper Critical - going high) Critical 65929 Over-Temperature
TrapID Description Severity 262528 Generic Predictive Fan Failure Cleared Information 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy has returned to Normal Information 2715392 Battery Low (Predictive Failure) Warning 2715520 Battery Low (Predictive Failure) Cleared Information 2715393 Battery Failure Critical 2715521 Ba
TrapID Description Severity 487306 CPU Throttle Cleared (Normal Processor Speed) Information 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy has returned to Normal Information 552704 Power Supply Inserted Information 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Information 552706 Power Supply Warning Warning 552834 Power Supply Warning Cle
drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage. The trap variables are defined in the Dell Remote Access Controller Out-of-Band Group section. Table 115. PowerEdge M1000e CMC traps TrapID Name Description Severity Category 2000 alertCMCTestTrap CMC has generated a test trap. Informational Error Events 2002 alertCMCNormalTrap CMC reported a returnto-normal or informational event. Normal Error Events 2003 alertCMCWarningTra CMC reported a warning Warning p event.
Table 117. Battery Traps TrapID Description Category SubCategory Severity Battery state has returned to Status Events normal; or battery presence had been detected. Battery Information al Battery is low. Status Events Battery Minor Battery has failed or battery is absent. Error Events Battery Critical Description Category SubCategory Severity Cable failure. Error Events Cable Critical Description Category SubCategory Severity Chassis Management Controller detected a warning.
Table 121. Hardware Configuration Traps TrapID Description Category SubCategory Severity Status Events Hardware Configuration Information al Status Events Hardware Configuration Minor Error Events Hardware Configuration Critical Category SubCategory Severity IO Virtualization Information al Status Events IO Virtualization Minor IO Virtualization failure or critical event. Error Events IO Virtualization Critical Description Category SubCategory Severity Link status information.
Table 124. PCI Device Traps TrapID Description Category SubCategory Severity PCI device information. Status Events PCI Device Information al PCI device warning. Status Events PCI Device Minor PCI device failure or critical event. Error Events PCI Device Critical Description Category SubCategory Severity Power supply has returned to normal. Status Events Power Supply Information al Power supply has detected a Status Events warning.
Table 128. Redundancy Traps TrapID Description Category SubCategory Severity Status Events Redundancy Information al Redundancy is degraded. Status Events Redundancy Minor Redundancy is lost. Error Events Redundancy Critical Description Category SubCategory Severity Security information. Status Events Security Information al Security warning. Status Events Security Minor Security failure or critical event.
TrapID Description Category SubCategory Severity Status Events Software Configuration Minor Category SubCategory Severity Status Events Temperature Information al Status Events Temperature Minor Error Events Temperature Critical Description Category SubCategory Severity Voltage sensor reading is within range. Status Events Voltage Information al Voltage sensor has detected Status Events a warning value. Voltage Minor Voltage sensor has detected Error Events a failure value.
TrapID Description Category Subcategory Severity Error Events Battery Critical Category Subcategory Severity Error Events Controller Information al Error Events Controller Minor Error Events Controller Critical Category Subcategory Severity Error Events Enclosure Information al Error Events Enclosure Minor Storage enclosure failure. Error Events Enclosure Critical Description Category Subcategory Severity Storage fan information.
Table 138. Storage Physical Disk Traps TrapID Description Category Subcategory Severity Error Events Physical Disk Information al Error Events Physical Disk Minor Storage physical disk failure.
TrapID Description Category Subcategory Severity 4177 Storage Management has Error Events detected a device independent error condition. There is no global status change associated with this trap.
TrapID Description Category SubCategory Severity 8690 Chassis Management Controller audit warning. Status Events CMC Minor Chassis Management Controller audit failure or critical event. Error Events CMC Critical Category SubCategory Severity Status Events IO Virtualization Minor Description Category SubCategory Severity License information. Status Events License Information al License warning. Status Events License Minor License failure.
Table 148. Audit Power Usage Traps TrapID Description Category SubCategory Severity Status Events Power Usage Minor Error Events Power Usage Critical Category SubCategory Severity Error Events Software Change Critical alert2PowerUsageAuditWarning 8418 Power usage audit warning. alert2PowerUsageAuditFailure 8417 Power usage audit failure or critical event. Table 149.
iDRAC8 MIB 4 The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRACSMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 8 (iDRAC8). This MIB provides management data that allows you to monitor devices and software on a system via an out-ofband connection to the iDRAC8 of a system. NOTE: From iDRAC7 firmware release r1.30.
SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1, v2c and v3 TRAP SNMP v1, SNMP v2c and SNMP v3 NOTE: iDRAC8 does not support the SNMP SET operation for any data. NOTE: iDRAC7 firmware release r1.30.30 or later and iDRAC8 supports SNMP query operations (GET, GETNEXT, GETBULK) via the SNMPv3 protocol. In addition to supporting query operations via the SNMP v1 and SNMP v2c protocols, SNMP User Security Model (USM) is supported.
Description This attribute defines the product name of a remote access card. Syntax StringType Access Read-only Table 154. RAC Short Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access Read-only Table 155. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card.
Access Read-only Table 159. RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only Table 160. RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This attribute defines the firmware version of a remote access card.
Table 163. Chassis Model Modular Name chassisModelModular Object ID 1.3.6.1.4.1.674.10892.5.1.2.3.0 Description This attribute defines the model of the modular chassis. The value is zero length if not a modular system. Syntax StringType Access Read-only System Information Group The System Information Group objects provide information about the system in which the iDRAC resides. Table 164. System Fully Qualified Domain Name Name systemFQDN Object ID 1.3.6.1.4.1.674.10892.5.1.3.1.
Table 168. System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.6.1.4.1.674.10892.5.1.3.5.0 Description This attribute defines the slot number of the blade in the chassis. Syntax StringType Access Read-only Table 169. System Operating System Name Name systemOSName Object ID 1.3.6.1.4.1.674.10892.5.1.3.6.0 Description This attribute defines the name of the operating system that the host is running. Syntax StringType Access Read-only Table 170.
Description This attribute defines the Rack locator of the system. Syntax StringType Access Read-only Table 174. System Rack Slot Name systemRackSlot Object ID 1.3.6.1.4.1.674.10892.5.1.3.11.0 Description This attribute defines the Rack Slot locator of the system. Syntax StringType Access Read-only Table 175. System Model Name Name systemModelName Object ID 1.3.6.1.4.1.674.10892.5.1.3.12.0 Description This attribute defines the model name of the system.
Access Read-only Table 179. System Chassis System Height Name systemChassisSystemHeight Object ID 1.3.6.1.4.1.674.10892.5.1.3.16.0 Description This attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component. Syntax INTEGER Access Read-only Table 180. System Blade Geometry Name systemBladeGeometry Object ID 1.3.6.1.4.1.674.10892.5.1.3.17.
Description This attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included. Syntax ObjectStatusEnum Access Read-only Table 184. Global Storage Status Name globalStorageStatus Object ID 1.3.6.1.4.1.674.10892.5.2.3.0 Description This attribute defines the overall storage status being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 185. System Power State Name systemPowerState Object ID 1.3.
iDRAC8 Traps The iDRAC8 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC8 Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC8. The iDRAC8 generates events in response to changes in the status of sensors and other monitored parameters. When an event with predefined characteristics occurs on your system, the SNMP subagent sends information about the event, along with trap variables, to the management console.
Table 188. Alert Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.5.3.1.2.0 Description Message describing the alert. Syntax StringType Table 189. Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 190. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.
Table 194. Alert Message Arguments Variable Name alertMessageArguments Object ID 1.3.6.1.4.1.674.10892.5.3.1.8.0 Description Concatenated set of strings representing the message arguments of the event. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 195.
Table 198. Automatic System Recovery Trap TrapID Description Category SubCategory Severity Automatic system recovery (ASR) was performed. System Health Auto Sys Reset Critical Description Category SubCategory Severity Battery state has returned to System Health normal; or battery presence had been detected. Battery Event Information al Battery is low. System Health Battery Event Minor Battery has failed or battery is absent.
Table 202. Fan Traps TrapID Description Category SubCategory Severity Fan information. System Health Fan Event Information al Fan warning. System Health Fan Event Minor Fan failure. System Health Fan Event Critical Description Category SubCategory Severity Fiber Channel information. System Health Fiber Channel Information al Fiber Channel warning. System Health Fiber Channel Minor Fiber Channel failure or critical event.
TrapID Description Category SubCategory Severity Memory device status is noncritical. System Health Memory Minor Memory device status is critical. System Health Memory Critical Description Category SubCategory Severity Network information. System Health NIC Config Information al Network warning. System Health NIC Config Minor Network failure or critical event.
TrapID Description Category SubCategory Severity 2417 An error was detected for a PCI device. System Health PCI Device Critical Description Category SubCategory Severity Physical disk information. System Health Physical Disk Information al Physical disk warning. System Health Physical Disk Minor Physical disk failure. System Health Physical Disk Critical Description Category SubCategory Severity System BIOS detected a failure.
Table 213. Power Usage Traps TrapID Description Category SubCategory Severity System performance restored. System Health Power Usage Information al System performance degraded. System Health Power Usage Minor The system halted because system power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold. System Health Power Usage Critical Description Category SubCategory Severity Redundancy information.
Table 216. Integrated Dual SD Module Absent Trap TrapID Description Category SubCategory Severity System Health IDSDM Absent Critical Category SubCategory Severity System Health IDSDM Redundancy Information al System Health IDSDM Redundancy Minor System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Information al Security failure or critical event.
Table 220.
Table 223. vFlash Media Device Absent Trap TrapID Description Category SubCategory Severity vFlash Media device is absent. System Health vFlash Absent Information al Description Category SubCategory Severity RAC information. System Health RAC Information al Description Category SubCategory Severity Voltage sensor reading is within range. System Health Voltage Information al Voltage sensor has detected System Health a warning value.
TrapID Description Category SubCategory Severity Battery is low. Storage Battery Event Minor Battery has failed or battery is absent. Storage Battery Event Critical Description Category SubCategory Severity Storage Storage Contr Information al Storage Storage Contr Minor Controller failure. Storage Storage Contr Critical Description Category SubCategory Severity Storage Storage Enclosr Information al Storage Storage Enclosr Minor Enclosure failure.
Table 231. Physical Disk Traps TrapID Description Category SubCategory Severity Storage Physical Disk Information al Storage Physical Disk Minor Storage Physical Disk Critical Category SubCategory Severity Storage Power Supply Information al Storage Power Supply Minor Storage Power Supply Critical Category SubCategory Severity Storage Information al Storage Minor Storage Critical Storage Physical Disk Information 4347 Physical disk information.
Table 234. Temperature Probe Traps TrapID Description Category SubCategory Severity Storage Temperature Information al Storage Temperature Minor Temperature probe failure. Storage Temperature Critical Description Category SubCategory Severity Storage Virtual Disk Information al Storage Virtual Disk Minor Storage Virtual Disk Critical Storage Temperature Probe Information 4211 Temperature probe information. Storage Temperature Probe Warning 4210 Temperature probe warning.
TrapID Description Category SubCategory Severity 8594 Debug authorization failed. Audit Debug Minor Description Category SubCategory Severity User tracking warning. Audit User Tracking Minor Description Category SubCategory Severity iDRAC IP address has changed. Audit DRAC IP Address Informational Description Category SubCategory Severity License information. Audit Licensing Informational License warning. Audit Licensing Minor License failure.
TrapID Description Category SubCategory Severity 10635 Auto discovery information. Configuration DIS Informationa l TrapID Description Category Severity 10771 Network configuration information. Configuration IOID Informationa l 10770 Network configuration warning.