Release Notes

Solution: To view the Fluid Cache details through CLI or GUI, connect to Fluid cache
through CLI or GUI.
o
CLI Command to connect to Fluid Cache: omconfig storage fluid cache
action=connect
o
GUI Command to connect to Fluid Cache: Although Fluid Cache details are
not enumerated in GUI after system reboot, Fluid Cache component is
enumerated in Storage component tree.
Steps to connect:
1.
Click on Fluid Cache component listed under storage tree.
2.
Click on “Connect Fluid Cache” option to connect to Fluid Cache.
DAS Fluid Cache License cannot be applied through DWS Client.
After hot removing the PCIe SSD which is part of Fluid Cache Pool, the Fluid Cache Pool does not
display the updated value of Cache Count.
BITS118226: The representation of NVMe devices residing on backplanes that attach to PCIe
Extender cards is inaccurate on Storage Management. This is because Storage Management does
not have a process to understand the mapping of the NVMe device, backplane, and the PCIe
Extender card. This issue exists only on PowerEdge R920 servers and does not impact the
operations on the NVMe device. Multiple backplanes on Server Administrator indicates the
presence of multiple PCIe Extender cards on the system.
BITS124349: Firmware version for SAS 9207_8e, SAS 9206_16e, and SAS 9300_8e, will not be
displayed on Storage Management GUI and CLI.
BITS123999: SAS 9300_8e is not supported on systems running the VMware ESXi operating
system.
BITS128355: The slot occupancy report displays single backplane ID and backplane name in GUI
and CLI.
The physical disk slot occupancy report for PCIe Subsystem displays NVMe devices present in
two different PCIe backplanes under the same PCIe backplane on PowerEdge R920 servers. The
NVMe devices connected to different PCIe backplanes are displayed correctly under Storage -->
PCIe-SSD Subsystem --> PCIe-SSD Extender --> Enclosure.
BITS128540: The firmware version of the storage controller is not present under Storage -->
Controller --> Firmware/Driver Version. The information is displayed under Storage -->
Controller --> Information/Configuration.
BITS146054: The enclosure automatically sets the critical and default warning thresholds. The
user cannot set or reset any warning threshold to any temperature probe through the storage
management GUI or CLI.
On a PowerEdge server with maximum configuration of 8 populated enclosures connected to
the PERC hardware controller, the user can experience a delay in response. When Server
Administrator storage commands such as Create Virtual Disk or Start check consistency are run,
the delay in response can range from 10 30 minutes.
BITS148893: When creating a virtual disk on S130 controller (software RAID), if you do not select
the first option under “Assign Dedicated Hot Spare” a message appears: “DHS not assigned to VD".
When you create a virtual disk on a software RAID controller using the “Create Virtual Disk”