Glossary

Property Definition
Rebuild Rate Rebuild rate is the percentage of resources available on a system
dedicated to rebuild a failed disk when necessary. For more
information on rebuild rate, see Setting The Rebuild Rate.
NOTE: The value for the Revertible Hot Spare operation is the
same as the value set for the Rebuild Rate property.
BGI Rate The background initialization (BGI) rate is the percentage of resources
available on a system dedicated to perform the background
initialization of a virtual disk after it is created. For more information on
BGI rate, see Setting Background Initialization Rate.
Check Consistency Rate The check consistency rate is the percentage of resources available on
a system dedicated to perform check consistency on a redundant
virtual disk. For more information, see Performing A Check
Consistency.
Reconstruct Rate The reconstruct rate is the percentage of resources available on a
system dedicated to reconstruct a disk group after adding a physical
disk or changing the RAID level of a virtual disk residing on the disk
group. For more information on reconstruct rate, see Setting The
Reconstruct Rate.
Alarm State Displays whether the alarm on the controller is enabled or disabled.
NOTE: This property is displayed only for SCSI storage controllers.
Abort Check Consistency on
Error
Enables you to stop the Check Consistency operation on error. This
property is available only on controllers that have controller firmware
version 6.1 and later.
Allow Revertible Hot Spare
and Replace Member
Enables the automatic copying of data from a physical disk to a hot
spare (in case of predictive failure) or from a hot spare to a physical
disk (in case of replacement of a degraded disk). For more information,
see Enabling Revertible Hot Spare.
Load Balance Provides the ability to automatically use both controller ports or
connectors connected to the same enclosure to route I/O requests.
This property is available only on SAS controllers that have controller
firmware version 6.1 and later.
Auto Replace Member on
Predictive Failure
Enables the automatic copying of data from a physical disk to a hot
spare in case of predictive failure. Use this property in conjunction with
the Allow Revertible Hot Spare and Replace Member property.
Redundant path view Indicates whether Storage Management has detected a redundant path
configuration. Storage Management detects a redundant path
configuration when both controller ports are connected to the same
enclosure that is in a unified mode. For more information, see Setting
The Redundant Path Configuration.
68