Reference Guide
Power Budget
Attribute : Enable Power Cap
Values : Enabled
Attribute : Power Cap
Values : 400 W (56%)
NOTE: Power budget requires license to report the details. If the appropriate license is not installed
or has expired, the system does not display the power budget details. For more information, see the
Dell License Manager Guide at dell.com/support/manuals.
Omreport Chassis Pwrmonitoring Or Omreport Mainsystem Pwrmonitoring
Use the omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command to view the
properties of the system’s power consumption. The values display either in Watts or BTU/Hr based on the
configuration. Type:
omreport chassis pwrmonitoring
or
omreport mainsystem pwrmonitoring
For each power monitoring profile in the system, values display for the following fields:
• Power Consumption Status
• Probe Name
• Reading
• Warning Threshold
• Failure Threshold
• Amperage: Location and Reading
• Power Tracking Statistics
• Energy Consumption
• Measurement Start Time
• Measurement Finish Time
• Reading
• System Peak Power
• System Peak Amperage
NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is
applicable only on systems that support PMBus and that have hot-swappable power supplies and
not systems that have a fixed, non-redundant power supply installed.
NOTE: Power monitoring requires license to report the details. If the appropriate license is not
installed or has expired, the system does not display the power consumption details of the system.
For more information, see the Dell License Manager Guide at dell.com/openmanagemanuals.
NOTE: To maintain consistency across the commands, the output format of this command and the
subsequent command levels has changed. So, you may have to change the user scripts as
applicable.