Reference Guide

Example
omconfig storage globalinfo action=globalrescan
Omconfig Set Hot Spare Protection Policy
Table 113. Omconfig Set Hot Spare Protection Policy
Description Sets the hot spare protection policy for dedicated or global hot spares. For more
information, see the Dell OpenManage Server Administrator Storage
Management User’s Guide at dell.com/support/manuals.
Syntax
omconfig storage globalinfo action= setprotectionpolicies
type=dhs raid=<r1 | r5 | r6 | r10 | r50 | r60 | all>
hscount=<1-16> warnlevel=<0-3> includeghsinvdstate=<yes |
no>, where hscount is the number of hot spares assigned to the virtual disk and
warnlevel is the severity level you want to assign to the generated alert, if this
policy is violated. Use
hscount=0 warnlevel=0 to reset the dedicated hot
spare protection policy for the RAID level.
Example for Global hot spare protection policy
Example
omconfig storage globalinfo action=setprotectionpolicies
type=dhs hscount=1 warnlevel=1 includeghsinvdstate=yes
Omconfig Connector Commands
The following table displays the omconfig command syntax required to execute connector tasks.
Table 114. omconfig Connector Commands
Required Command
Levels (1, 2, 3)
Optional name=value pairs
omconfig storage
connector
action=rescan controller=id connector=id
Omconfig Rescan Connector
Description Rescans a controller connector. This command rescans all connectors on the
controller and is therefore similar to performing a controller rescan.
NOTE: This command is not supported on SAS controllers.
Syntax
omconfig storage connector action=rescan controller=id
connector=id, where id is the controller ID and the connector ID as reported
by the omreport command. To obtain these values, type omreport storage
controller
to display the controller IDs and then type omreport storage
connector controller=ID to display the IDs for the connectors attached to
the controller.
Example to Rescan connector 2 on controller 1.
174