Reference Guide
Example
omconfig storage controller action= clearforeignconfig controller=1
Omconfig Physical Disk Power Management
Descriptio
n
Manages the power of physical disks in a controller by spinning down hot spares,
configured drives, and unconfigured drives.
Syntax
omconfig storage controller action= setpdiskpwrmanagement
spindownunconfigureddrives= <enabled | disabled>
spindownhotspares=<enabled | disabled>
spindownconfigureddrives=<enabled | disabled> idlec=<enabled |
disabled> spindowntimeinterval=<30 to 1440>(minutes)
spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval= <1 to 24>(hours),
where id is the controller ID as reported by the omreport storage controller command.
NOTE: On PERC 7 controllers, only spindownunconfigureddrives,
spindownhotspares, and spindowntimeinterval parameters are supported.
NOTE: You can specify spinupstarttime and spinuptimeinterval only when
you set spindownconfigureddrives=enabled.
Example
to
Spin down drives that are not configured or hot spares that are unattended for 30 minutes
Example
omconfig storage controller action= setpdiskpwrmanagement
spindownunconfigureddrives= enabled spindownhotspares=enabled
spindowntimeinterval=30 controller=1
Omconfig Set Patrol Read Mode
Descriptio
n
Sets the patrol read mode for the controller.
Syntax
omconfig storage controller action= setpatrolreadmode controller=id
mode= manual|auto|disable, where id is the controller ID as reported by the
omreport storage controller command.
Example
to
Sets the patrol read on controller 1 to manual mode
Example
omconfig storage controller action= setpatrolreadmode controller=1
mode=manual
Omconfig Start Patrol Read
Descriptio
n
Starts the patrol read task on the controller.
Syntax omconfig storage controller action=startpatrolread controller=id,
where id is the controller ID as reported by the omreport storage controller command.
164