User's Manual
The cache policies are:
• Enabled — Disk Cache Policy is enabled.
• Disabled — Disk Cache Policy is disabled.
NOTE: The default setting for Disk Cache Policy for virtual disks based on SATA drives is Enabled;
and for virtual disks based on SAS drives is Disabled.
NOTE: For SAS 6i/R and PERC H200 family of controllers, the Disk Cache Policy setting is available
only after creating the virtual disk.
Background Initialization On PERC Controllers
On PERC controllers, background initialization of a redundant virtual disk begins automatically within 0 to
5 minutes after the virtual disk is created. The background initialization of a redundant virtual disk
prepares the virtual disk to maintain redundant data and improve write performance. For example, after
the background initialization of a RAID 5 virtual disk completes, the parity information is initialized. After
the background initialization of a RAID 1 virtual disk completes, the physical disks are mirrored.
The background initialization process helps the controller identify and correct problems that may occur
with the redundant data later. In this regard, the background initialization process is similar to a check
consistency.
The background initialization should be allowed to run to completion. If canceled, the background
initialization automatically restarts within 0 to 5 minutes. Some processes such as read and write
operations are possible while the background initialization is running. However, other processes such as
creating a virtual disk, cannot be run concurrently with background initialization. These processes cause
the background initialization to cancel.
Related Links
Canceling Background Initialization
Setting Background Initialization Rate
Non-RAID Controller Description
The non-RAID SCSI and SAS controllers are non-RAID controllers that support SCSI and SAS devices.
Because these controllers are non-RAID, they do not support virtual disks. You can manage these non-
RAID controllers and their attached SCSI and SAS devices with Storage Management.
NOTE: Supported features may vary from controller to controller.
Non-RAID SCSI Controllers
The LSI PCI-e U320 non-RAID controllers use Small Computer System Interface (SCSI) technology.
Non-RAID SAS Controllers
The following non-RAID controllers use Serial Attached SCSI (SAS) technology:
• SAS 5/i Integrated
• SAS 5/E
• SAS 6 Gbps Adapter
• LSI SAS 9207-8e
65