User's Manual
To Reconfigure a Virtual Disk (Changing the RAID Level and Size): Step 2 of 3
1. Select the new RAID level for the virtual disk — The available RAID levels depend on the number or
physical disks selected and the controller. The following describes the possible RAID levels:
– Depending on the controller, Concatenated enables you to combine the storage capacity of
several disks or to create a virtual disk using only a single physical disk. For information on
whether the controller supports a single physical disk or two or more when using Concatenated,
see Number Of Physical Disks Per Virtual Disk. Using Concatenated does not provide data
redundancy nor does it affect the read and write performance.
– Select RAID 0 for striping — This selection groups n disks together as one large virtual disk with a
total capacity of n disks. Data is stored to the disks alternately so that they are evenly distributed.
Data redundancy is not available in this mode. Read and write performance is enhanced.
– Select RAID 1 for mirroring disks — This selection groups two disks together as one virtual disk
with a capacity of one single disk. The data is replicated on both disks. When a disk fails, the
virtual disk continues to function. This feature provides data redundancy and good read
performance, but slightly slower write performance. The system must have at least two physical
disks to use RAID 1.
– Select RAID 5 for striping with distributed parity — This selection groups n disks together as one
large virtual disk with a total capacity of (n-1) disks. When a disk fails, the virtual disk continues to
function. This feature provides better data redundancy and read performance, but slower write
performance. The system must have at least three physical disks to use RAID 5.
– Select RAID 6 for striping with additional parity information — This selection groups n disks as
one large virtual disk with a capacity of (n-2) disks. Two sets of parity information are alternately
stored on all disks. The virtual disk remains functional with up to two disk failures.
– Select RAID 10 for striping over mirror sets — This selection groups n disks together as one large
virtual disk with a total capacity of (n/2) disks. Data is striped across the replicated mirrored pair
disks. When a disk fails, the virtual disk continues to function. The data is read from the surviving
mirrored pair disk. This feature provides the best failure protection, read and write performance.
The system must have at least four physical disks to use RAID 10.
2. In the Size field, type the size of the reconfigured virtual disk. The minimum and maximum allowable
size is displayed below the Size field. These values reflect the new capacity of the virtual disk after
any addition or deletion of physical disks which you may have chosen in Virtual Disk Task:
Reconfigure (Step 1 of 3).
NOTE: PERC S100 and S300 controllers do not allow you to change the RAID level.
3. Click Continue to go to the next page or Exit Wizard if you want to cancel.
Related Links
Reconfiguring A Virtual Disk
To Reconfigure A Virtual Disk Expand Virtual Disk Capacity: Step 2 of 3
1. Enter the percentage of the free disk size available by which you want to expand the virtual disk
capacity. The page displays the maximum free size available and the description of the selected RAID
level.
2. Click Continue to go to the next page or click Exit Wizard if you want to cancel.
Virtual Disk Task: Reconfigure (Step 3 of 3)
Does my controller support this feature? See Supported Features.
171